Product Main

Specifications

Economic models
TOS-2020CH / 2040CH / 2050CH

TOS-2020CF / 2040CF / 2050CF: with built-in 6 digits frequency counter

TOS-2020CT / 2040CT / 2050CT: with component test function

 
Features

Dual channel 20MHz/40MHz/50MHz

10 times sweep magnification

TV synchronization, X-Y mode

High illumination internal graticule CRT

Japanese encoded switch, reliable and durable

Fully sealed durable attenuation switch

ALT triggering function, enabling simultaneous observation of two independent signals

 
 
Specifications
MODEL
TOS-2020CH
TOS-2020CF
TOS-2040CT
TOS-2040CH
TOS-2040CF
TOS-2040CT
TOS-2050CH
TOS-2050CF
TOS-2050CT
Vertical system
 
Sensitivity

5mV~5V/DIV, 10 steps in 1-2-5 sequence

Sensitivity accuracy

≤3%; X5MAG: ≤5%

Vernier sensitivity

1/2.5 or less than panel indicated value

Bandwidth
DC (AC 10Hz)~20MHz
DC (AC 10Hz)~40MHz
DC (AC 10Hz)~50MHz
AC coupling

<10Hz (at 100kHz, 8DIV, frequency response -3dB)

Rise time
Approx.17.5ns
Approx.8.75ns
Approx.7ns
Input impedance
Approx.1MΩ//Approx.25pF

DC balance shift

5mV~5V/DIV: ±0.5DIV

Vertical mode

CH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INV

Chopping repetition frequency

Approx. 250kHz

Input coupling

AC, GND, DC

Max. Input voltage

300V peak-peak (AC: frequency≤1kHz)

Common mode rejection ratio

>50:1 at 50kHz sine wave (set CH1 and CH2 at same sensitivity)

CH2 INV BAL

Balanced point variation≤1DIV (referred to graticule center)

CH1 signal output
Not provided
 
MODEL
TOS-2020CH
TOS-2020CF
TOS-2040CT
TOS-2040CH
TOS-2040CF
TOS-2040CT
TOS-2050CH
TOS-2050CF
TOS-2050CT
Horizontal system
Sweep time base
0.2us~0.5s/DIV, 20 steps in 1-2-5 sequence

Sweep time base accuracy

±3%, X10MAG: ±5% (20ns~50ns/DIV uncalibrated)

Vernier sweep time base

≤1/2.5 of panel indicated value

Sweep magnification

X10 (Max. sweep time base 20ns/DIV)

Position shift caused by X10MAG

Within 2DIV at CRT screen center

Linearity

±5%, X10MAG: ±10% (0.2s~1us)

Trigger system
Trigger mode
AUTO, NORM, TV-V, TV-H
Trigger level lock
Not provided

Trigger source

CH1, CH2, LINE, EXT

Trigger coupling

AC: 20Hz to full bandwidth

Polarity
“+” or “-” polarity
Sensitivity
 
20Hz~2MHz
2MHz~20MHz
20MHz~40MHz
40MHz~50MHz
CH1, CH2
1DIV
1.5DIV
2.5DIV
3DIV
ALT
2DIV
3DIV
 
 
EXT
200mV
800mV
 
 
TV: Sync pulse>1DIV (EXT: 1V)

External trigger output signal

Input impedance: Approx.1MΩ//Approx.25pF
Max. input voltage: 300V (DC+AC peak), AC≤1kHz
Calibration signal
Waveform

Positive-going square wave

Frequency
Approx.1kHz
Duty ratio
<48:52

Output voltage

2Vp-p ±2%

Output impedance

Approx.1kΩ
X-Y mode
Sensitivity
5mV~5V/DIV, ±3%
Bandwidth
DC~500kHz (-3dB)

X-Y phase error

≤3°at DC~50kHz

Frequency counter (only for TOS-2020CF, TOS-2040CF, TOS-2050CF)

Display
6 digits LED
Display accuracy
0.01%

Component test (only for TOS-2020CF, TOS-2040CF, TOS-2050CF)

Testing subject

Resistor, capacitor, coil, diode, zener or simple combination of the components

Testing voltage

Approx.9Vac p-p

Testing frequency

50/60Hz

Testing current

Approx.0.6mA
CRT
Mode

6" rectangle, internal graticule

Display area
8×10DIV (1DIV=1cm)
Phosphor
P31

Accelerating voltage

Approx.2kV (20MHz); Approx.12kV (40MHz)

Trace rotation

Adjustable at front panel
General
Power source

AC110V/220V±10%, 50/60Hz, Max.35VA

Dimension
310×150×455mm
Accessories

Power cord ×1, Operation manual ×1, Probe ×2

Component test lead ×1 (only for TOS-2020CT, TOS-2040CT, TOS-2050CT)

Weight
Approx.8kg