TOS-2020BF / 2040BF / 2050BF: with built-in 6 digits frequency counter
|
Features
|
|
Dual channel 20MHz/40MHz/50MHz |
|
High sensitivity 1mV/DIV
|
|
Z-axis modulation input, CH1 signal output
|
|
10 times sweep magnification |
|
TV synchronization, X-Y mode |
|
High illumination internal graticule CRT |
|
Encoder for sweep and vertical mode switch
|
|
Fully sealed durable attenuation switch |
|
ALT triggering function, enabling simultaneous observation of two independent signals |
|
Trigger level lock function, Auto synchronize function |
|
Built-in 1000:1 attenuator, expanded vertical sensitivity to 10V~20V/DIV |
|
MODEL
|
TOS-2020B
TOS-2020BF
|
TOS-2040B
TOS-2040BF
|
TOS-2050B
TOS-2050BF
|
|
Vertical system
|
|||
|
Sensitivity
|
5mV~20V/DIV, 12 steps in 1-2-5 sequence |
||
|
Sensitivity accuracy
|
≤3%; X5MAG: ≤5% |
||
|
Vernier sensitivity
|
1/2.5 or less than panel indicated value
|
||
|
Bandwidth
|
DC~20MHz
(X5MAG: DC~7MHz) |
DC~40MHz
(X5MAG: DC~15MHz) |
DC~50MHz
(X5MAG: DC~15MHz) |
|
AC coupling
|
<10Hz (at 100kHz, 8DIV, frequency response -3dB) |
||
|
Rise time
|
Approx.17.5ns
(X5MAG: Approx.50ns)
|
Approx.8.75ns
(X5MAG: Approx.25ns)
|
Approx.7ns
(X5MAG: Approx.23.3ns)
|
|
Input impedance
|
Approx.1MΩ//Approx.25pF
|
||
|
DC balance shift |
5mV~5V/DIV: ±0.5DIV |
||
|
Vertical mode |
CH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INV
|
||
|
Chopping repetition frequency |
Approx. 250kHz |
||
|
Input coupling |
AC, GND, DC
|
||
|
Max. Input voltage |
300V peak-peak (AC: frequency≤1kHz) |
||
|
Common mode rejection ratio |
>50:1 at 50kHz sine wave (set CH1 and CH2 at same sensitivity) |
||
|
CH2 INV BAL
|
Balanced point variation≤1DIV (referred to graticule center) |
||
|
CH1 signal output
|
Min.20mV/DIV (50Ω output bandwidth 50Hz~5MHz) |
||
|
MODEL
|
TOS-2020B
TOS-2020BF
|
TOS-2040B
TOS-2040BF
|
TOS-2050B
TOS-2050BF
|
|||||
|
Horizontal system
|
||||||||
|
Sweep time base
|
0.2us~0.5s/DIV, 20 steps in 1-2-5 sequence
|
|||||||
|
Sweep time base accuracy |
±3%, X10MAG: ±5% (20ns~50ns/DIV uncalibrated)
|
|||||||
|
Vernier sweep time base |
≤1/2.5 of panel indicated value |
|||||||
|
Sweep magnification |
X10 (Max. sweep time base 20ns/DIV)
|
|||||||
|
Position shift caused by X10MAG |
Within 2DIV at CRT screen center |
|||||||
|
Linearity
|
±5%, X10MAG: ±10% (0.2s~1us) |
|||||||
|
Trigger system
|
||||||||
|
Trigger mode
|
AUTO, NORM, TV-V, TV-H
|
|||||||
|
Trigger level lock
|
Provided
|
|||||||
|
Trigger source |
CH1, CH2, LINE, EXT |
|||||||
|
Trigger coupling |
AC: 20Hz to full bandwidth |
|||||||
|
Polarity
|
“+” or “-” polarity |
|||||||
|
Sensitivity
|
|
20Hz~2MHz
|
2MHz~20MHz
|
20MHz~40MHz
|
40MHz~50MHz
|
|||
|
CH1, CH2
|
1DIV
|
1.5DIV
|
2.5DIV
|
3DIV
|
||||
|
ALT
|
2DIV
|
3DIV
|
|
|
||||
|
EXT
|
200mV
|
800mV
|
|
|
||||
|
TV: Sync pulse>1DIV (EXT: 1V)
|
||||||||
|
External trigger output signal |
Input impedance: Approx.1MΩ//Approx.25pF
Max. input voltage: 300V (DC+AC peak), AC≤1kHz
|
|||||||
|
Z-axis
|
||||||||
|
Sensitivity
|
5Vp-p
|
|||||||
|
Bandwidth
|
DC~2MHz
|
|||||||
|
Input impedance
|
Approx.47kΩ
|
|||||||
|
Max. input voltage
|
30V (DC+AC peak, AC frequency≤1kHz) |
|||||||
|
Calibration signal
|
||||||||
|
Waveform
|
Positive-going square wave |
|||||||
|
Frequency
|
Approx.1kHz
|
|||||||
|
Duty ratio
|
<48:52
|
|||||||
|
Output voltage |
2Vp-p ±2%
|
|||||||
|
Output impedance |
Approx.1kΩ
|
|||||||
|
X-Y mode
|
||||||||
|
Sensitivity
|
5mV~5V/DIV, ±3%
|
|||||||
|
Bandwidth
|
DC~500kHz (-3dB) |
|||||||
|
X-Y phase error |
≤3°at DC~50kHz |
|||||||
|
Frequency counter (only for TOS-2020BF, TOS-2040BF, TOS-2050BF)
|
||||||||
|
Display
|
6 digits LED
|
|||||||
|
Display accuracy
|
0.01%
|
|||||||
|
CRT
|
||||||||
|
Mode
|
6" rectangle, internal graticule |
|||||||
|
Display area
|
8×10DIV (1DIV=1cm)
|
|||||||
|
Phosphor
|
P31
|
|||||||
|
Accelerating voltage |
Approx.2kV (20MHz); Approx.12kV (40MHz) |
|||||||
|
Trace rotation |
Adjustable at front panel
|
|||||||
|
General
|
||||||||
|
Power source
|
AC110V/220V±10%, 50/60Hz, Max.35VA |
|||||||
|
Dimension
|
310×150×455mm
|
|||||||
|
Accessories
|
Power cord ×1, Operation manual ×1, Probe ×2 |
|||||||
|
Weight
|
Approx.8kg
|
|||||||

