AC Power Source Three Phase Output
|
Introduction |
|
The TFC63 series are three phase output AC power source, output capacity from 500VA to 800kVA. Adopting PWM high frequency technology & IGBT regulation mode, the TFC63 series features constant frequency and voltage with high accuracy. The input and output are galvanically isolated. The TFC63 series can be used to simulate grids of different countries, widely used in laboratories, production calibration & test and military applications.
|
|
Features |
|
ü Output voltage: phase voltage 0-300V, line voltage 0-520V ü Output frequency: 50Hz, 60Hz, 47-63Hz, 100Hz, 200Hz, 400Hz ü Phase difference: 120°±2° ü High accuracy LED display for voltage, current, frequency, active power, power factor ü Fast transient response, response time no more than 2ms for 100% load and unload ü Multiple protections: OVP, OCP, OTP and OLP ü Optional: RS-232/RS-485 interface for PC remote control on output frequency and voltage ü Optional: DC0-5V analog input for output control ü Customized specifications and functions acceptable
|
Specifications
|
Model |
6303 |
6306 |
6310 |
6315 |
6320 |
6330 |
6345 |
|||||||
|
Total output capacity |
3KVA |
6KVA |
10KVA |
15KVA |
20KVA |
30KVA |
45KVA |
|||||||
|
Output capacity/phase |
1KVA |
2KVA |
3.3KVA |
5KVA |
7KVA |
10KVA |
15KVA |
|||||||
|
Circuit mode |
IGBT/PWM |
|||||||||||||
|
Input |
3φ4W, 380V±10% 50/60Hz |
|||||||||||||
|
Optional 1φ2W, 220V±10% 50/60Hz |
|
|
||||||||||||
|
Output |
||||||||||||||
|
Phase |
3 phase, Phase difference: 120°±2° |
|||||||||||||
|
Low range |
Phase voltage 0V-150V, Line voltage 0-260V |
|||||||||||||
|
High range |
Phase voltage 0V-300V, Line voltage0-520V |
|||||||||||||
|
Frequency |
50Hz, 60Hz, 40-70Hz, optional 400Hz |
|||||||||||||
|
Max. current |
0V-150V |
8.4A |
16.8A |
28A |
42A |
58A |
84A |
126A |
||||||
|
0V-300V |
4.2A |
8.4A |
14A |
21A |
29A |
42A |
63A |
|||||||
|
Frequency accuracy |
≤0.01% |
|||||||||||||
|
Line regulation |
≤1% |
|||||||||||||
|
Load regulation |
≤1% |
|||||||||||||
|
Harmonic distortion |
≤2% (tested with resistive load) |
|||||||||||||
|
Response time |
Max. 2ms |
|||||||||||||
|
Efficiency |
≥80% |
|||||||||||||
|
Meter & Resolution |
||||||||||||||
|
Frequency meter |
4 digits LED, resolution 0.1Hz |
|||||||||||||
|
Voltmeter |
4 digits LED, resolution 0.1V |
|||||||||||||
|
Ammeter |
4 digits LED, resolution 0.1A / 0.01A |
|||||||||||||
|
Power meter |
4 digits LED, resolution 0.01kW/ 0.001kW |
|||||||||||||
|
Preset function |
Preset output voltage, output frequency and output voltage floating ratio |
|||||||||||||
|
Hot key function |
Hot key for frequency switch, output voltage floating selection |
|||||||||||||
|
Alarm function |
Audio and visual alarm started once protection device is activated. Error code will be displayed. |
|||||||||||||
|
Protection |
Fuse switch for input and output; Fast-response circuit to detect over voltage, over current, over load, over temperature and short circuit; Output will be shut down in protection mode. |
|||||||||||||
|
Cooling |
Forced ventilation |
|||||||||||||
|
Cabinet protection grade |
IP2X |
|||||||||||||
|
Operation environment |
0℃-45℃, ≤90% RH(Non-condensing), Altitude: 1500 feet |
|||||||||||||