| Items | H3000 Frequency Converter | ||||||||
| Power supply | Rated voltage, Frequency | Three-phase 380V 50/60Hz; One-phase 220V 50/60Hz | |||||||
| Voltage range | 380V:330~440V; 220V:170~240V | ||||||||
| output | Voltage range | 380V:0~380V; 220V: 0~220V | |||||||
| Frequency range | 0.10~400.00Hz | ||||||||
| Control method | V/F control, space vector control | ||||||||
| Indication | Operating status/Alarm definition/ Interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the temperature and so on | ||||||||
| Control specifications | Output frequency range | 0.10Hz~400.00Hz | |||||||
| Frequency setting resolution | Digital input: 0.01Hz, analog input: 0.1% of max output frequency | ||||||||
| output frequency accuracy | 0.01Hz | ||||||||
| V/F control | Setting V/F curve to satisfy various load requirements | ||||||||
| Torque control | Auto increase: auto raise torque by loading condition; Manual increase: enable to set 0.0~20.0% of raising torque | ||||||||
| Multifunctional input Terminal | 8 multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, up/down function and emergency stop and other functions | ||||||||
| Multifunctional output Terminal | 3 multi-function output terminals for displaying of running, zerospeed, counter, external abnormity, program operation and other inforamtion and warnings | ||||||||
| Acceleration/ deceleration time setting | 0~6000s acceleration/deceleration time can be set individually | ||||||||
| Other functions | PID control | Buliti-in PID control | |||||||
| RS485 | Standard RS485 communication function (MODBUS) | ||||||||
| Frequency setting | Analog input: 0 to 10V, 0 to 20mA can selected Digital input: Input using the setting dial of the operation panel or RS485 or Up/Down | ||||||||
| Multi-speed | Eight multifunction input terminals. 15 section speed can be set | ||||||||
| Automatic voltage regulation | Automatic voltage regulation function can be selected | ||||||||
| Counter | Built-in 2 group of counters | ||||||||
| Protection /Waring functions | Overload | 150%, 60 second (constant torque); 120%, 60 second (variable torque) | |||||||
| Over voltage | Over voltage protection can be set | ||||||||
| Under voltage | Under voltage protection can be set | ||||||||
| Other protections | Overheat, output shortcircuit, over current, and parameter lock and so on | ||||||||
| Environment | Ambient temperature | -10°C to 40°C (non-freezing) | |||||||
| Ambient humidity | Max 95% (non-condensing) | ||||||||
| Altitude | Lower than 1000m | ||||||||
| Vibration | Max 0.5G | ||||||||
| Structure | Cooling Mode | Forced air cooling | |||||||
| Protective structure | IP 20 | ||||||||
| Installation Mode | Below 90KW: wall mounted; 110~200KW: wall mounted or in cabinet; Above 220KW: in cabinet | ||||||||