Product Main

Specifications

Items H3000 Frequency Converter
Power supply Rated voltage, Frequency Three-phase 380V 50/60Hz; One-phase 220V 50/60Hz
Voltage range 380V:330~440V; 220V:170~240V
output Voltage range 380V:0~380V; 220V: 0~220V
Frequency range 0.10~400.00Hz
Control method V/F control, space vector control
Indication Operating status/Alarm definition/ Interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the  temperature and so on
Control specifications Output frequency range 0.10Hz~400.00Hz
Frequency setting resolution Digital input: 0.01Hz, analog input: 0.1% of max output frequency
output frequency accuracy 0.01Hz
V/F control Setting V/F curve to satisfy various load requirements
Torque control Auto increase: auto raise torque by loading condition;                                                                                                                                                  Manual increase: enable to set 0.0~20.0% of raising torque
Multifunctional input Terminal 8 multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, up/down function and emergency stop and other functions
Multifunctional output Terminal 3 multi-function output terminals for displaying of running, zerospeed, counter, external abnormity, program operation and other inforamtion and warnings
Acceleration/ deceleration time setting 0~6000s acceleration/deceleration time can be set individually
Other functions PID control Buliti-in PID control
RS485 Standard RS485 communication function (MODBUS)
Frequency setting  Analog input: 0 to 10V, 0 to 20mA can selected                                                                                                                                            Digital input: Input using the setting dial of the operation panel or RS485 or Up/Down
Multi-speed Eight multifunction input terminals. 15 section speed can be set
Automatic voltage regulation Automatic voltage regulation function can be selected
Counter Built-in 2 group of  counters
Protection /Waring functions Overload 150%, 60 second (constant torque); 120%, 60 second (variable torque)
Over voltage Over voltage protection can be set
Under voltage Under voltage protection can be set
Other protections Overheat, output shortcircuit, over current, and parameter lock and so on
Environment Ambient temperature -10°C to 40°C (non-freezing)
Ambient humidity Max 95% (non-condensing)
Altitude Lower than 1000m
Vibration Max 0.5G
Structure Cooling Mode Forced air cooling
Protective structure IP 20
Installation Mode Below 90KW: wall mounted;                                                                                                                                      110~200KW: wall mounted or in cabinet;                                                                                                                               Above 220KW: in cabinet