| VOLTAGE RANGE | 88~264VAC/125~373VDC(surge for 5sec.Without damage) | ||||||
| FREQUENCY RANGE | 47~63Hz | ||||||
| EFFICENCY(Typ.) | 73.5% | 78.5% | 81.5% | 83.5% | 86.0% | 86.0% | 86.0% |
| AC CURRENT(Typ.) | 4.0A/115VAC 3.0A/230VAC | ||||||
| INRUSH CURRENT(Typ.) | COLD START: 30A/230VAC | ||||||
| LEAKAGE CURRENT | <2mA/240VAC | ||||||
| OVER LOAD | 110~180%rated output power | ||||||
| Protection type:Hiccup mode,recovers automatcally after fault condition is removed | |||||||
| OVER VOLTAGE | 3.8~4.45V | 5.75~6.75V | 13.8~16.2V | 17.25~20.25V | 27.6~32.4V | 40.0~45.5V | 55.2~64.8V |
| Protection type:Shut down O/P voltage,re-power on to recover | |||||||
| WORKING TEMP. | 20~+70℃(Refer to "Derating Curve") | ||||||
| WORKING HUMIDITY | 20~90%RH non-condensing | ||||||
| STORAGE TEMP.,HUMIDITY | 40~+85℃,10~95%RH | ||||||
| TEMP.COEFFICIENT | ±0.03%/℃(0~50℃) | ||||||
| VIBRATION | 10~50HZ, 5G 10min/1cycie,60min.each alongX, Y, Z axes | ||||||
| SAFETY STANDARDS | UL609501 TUV EN60950-1 approved | ||||||
| WITHSTAND VOLTAGE | I/PO/P, 3KVAC I/PFG: 1.5KVAC O/PFG: 0.5KVAC | ||||||
| ISOLATION RESISTANCE | I/PO/P, I/PFG, O/PFG: 100M Ohms/500VDC/25℃/70%RH | ||||||
| EMI EMISSION | Compliance to EN55022(CISPR22)Class B,EN61000-3-2,-3 | ||||||
| EMS IMMUNITY | Compliance to EN6100042,3,4,5,6,8,11,Iight industry level, criteria A | ||||||
| MTBF | 309.7K hrs min.. MILHDBK217F(25℃) | ||||||
| DIMENSION | 107*76.7*33.6mm(L*W*H) | ||||||
| PACKING | 0.3Kg: 60PCS/19Kg/0.46CUFT | ||||||