xlpe cable applied
on 1st Youth Olympic Games Singpore
Province-grade Research Lab
launched in our factory.
Brand: RMJT

 
PVC/XLPE Insulated Power Cable
Introduction:
The products can be produced according to our factory specification which is equivalent to the standard IEC60502. The factory can also design and manufacture special XLPE cable according to the other standards required by the customers. They not only have excellent electric, mechanical properties, but also have powerful resistance against chemical corrosion, heataging and environmental stress. Their structures are simple. The permissible maximum operating temperature is 90C. It is convenient for using, and they can be laid with no restriction of different elevation.

The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35
No of Core and Range of sectional Area (mm2)

1 Core 1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core 1.5-185 25-185
3 Core 1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core 2.5-400 25-400
5 Core 2.5-400 25-400
Conductor :
Cu Core Al Core
The Type and Main Application
(1) YJV
YJY YJLV
YJLV XLPE insulated, PVC or PE Sheathed Power Cable For laying indoor, tunnel, channel and undergroud, Unable to bear external mechanical force, but bear the traction force during laid
(2)YJV22
YJV22 YJLV22
YJV22 XLPE Insulated, Steel Tape Armoured, PVC or PE Sheathed Power Cable For laying indoor, tunnel, channel and undergroud Able to bear external mechanical force, but unable to bear large pulling force
(3)YJV32
YJV32 YJLV32
YJLV32 XLPE Insulated, Fine Steel Wire Armoured, PVC or PE Sheathed Power Cable For laying in shaft with large difference of level. Able to bear external machanical force and maderate pulling force
(4)YJV42
YJV42 YJLV42
YJLV42 XLPE Insulated, Thick Steel Wire Armoured, PVC or PE Sheathed Power Cable Able to bear positive pressure and pulling force

Note:
"ZR-"Include ABC three kinds of flame retardent cables, which are spectively indicated in "ZRA-" or "ZRB-" "ZRC-". For example: "ZRB-YJV""ZRA-YJV22".

Main Technical Quota
1. DC resistance:
Conductor resistance of finished cable at 20Cper kilometer is not more than the following values.

Nominal Section
Area(mm2)
:1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper Core: 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 
Aluminium core: 18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.778 0.0605 0.0469 0.0367

2. Voltage Test and Partial Discharge Test

Rate
Voltage Uo(kv)
Item
0.6/1 1.8/3 3.6/6 6/6
6/10 8.7/10
8.7/15 12/20 18/20
18/30 21/35 26/35
Voltage Test Voltage 3.5 6.5 12.5 21 30.5 42 63 73.5 91
Test Time 5 5 5 5 5 5 5 5 5
Partial Discharge Test Test Voltage - - 6.2 10.4 15.1 20.8 31.1 36.3 45
Discharge Capacity - - 10 10 10 10 10 10 10....