Full Digital Ultrasonic Diagnostic Equipment
Leading Digital TechnologyDBF:Digital Beam FormerRDF:Real-time Dynamic FilteringDFS:Dynamic Frequency ScanningRDA:Real-time Dynamic Aperture
Features:
???????
Trolley design14 inch high-resolution monitor8 TGC controlsHigh-quality imagesBroadband multi-frequency probesCineloopPermanent image storageUSB port
Imaging Processing:
- Planar images
- The functions of frame correlation, γ correction and edge enhancement held, as well as the functions of pretreatment, post processing, left-eight reversing and up-down reversing
- Image displaying ratio: step-less magnification which can be increased. Real-time local zooming held
- Maximum storage of more than 100,000 images. Images recorders optional
- Case history created and created automatically
- Images manage system, Case history database system and diagnosis & measurement pre-treat system
Technical Specification:
Display 14 inch high-resolution monitor
Scanning mode Electronic linear array, electronic convex linear
Display mode B, B/B, B/M, M, 4B
Magnification ×1.0, ×1.2, ×1.5, ×2.0
Gray Scale 256 level
Displaying depth 240mm, and depth could be increased and stepless
magnified
Resolution Horizontal: ≤2mm Vertical: ≤1mm
Geometrical precision ≤5%
Blind area ≤3mm
TGC 8-section TGC adjust
Image Polarity left/right turn, positive /negative turn and
up / down turn
Cineloop successive 256 frames
Output Interface two output interfaces, VGA and PAL video signal
output
Power Supply Range AC 110V 60Hz AC 220V 50Hz
Focusing modes dynamic-emitting focus, dynamic-receiving focus,
dynamic aperture, adaptive acoustic lens
Output interface AV, S-video, VGA
USB connector Yes
Measurement and Analysis Software:
- The General Measurement and Analysis
- The Measurement and Analysis for Gynecology
- The Measurement and Analysis for Obstetrics
- The Measurement and Analysis for Urology
- The Measurement and Analysis for Small parts
- The Measurement and Analysis for Heart and the ambient vessels
Remarks: for each picture there are more than 5 parameters for reference, such as distance, area, perimeter, angle, volume, gestational age, fetus’ weight, heart rate, slope rate, flux, left ventricle and so on
Standard Configuration:
- Main unit
- 14 inch monitor
- 256-frame cineloop
- Images permanent image storage
- Two probe connectors
- USB port
- 3.5MHz electronic convex transducer (2.5/5.0MHz)
Optional:
- Electronic transvaginal transducer (5.0/7.5MHz)
- Electronic High-frequency linear transducer (6.5/8.5MHz)
- MSF: Mass storage
- Jet printer, laser printer, video printer
- DICOM 3.0 interface
Leading Digital TechnologyDBF:Digital Beam FormerRDF:Real-time Dynamic FilteringDFS:Dynamic Frequency ScanningRDA:Real-time Dynamic Aperture
Features:
???????
Trolley design14 inch high-resolution monitor8 TGC controlsHigh-quality imagesBroadband multi-frequency probesCineloopPermanent image storageUSB port
Imaging Processing:
- Planar images
- The functions of frame correlation, γ correction and edge enhancement held, as well as the functions of pretreatment, post processing, left-eight reversing and up-down reversing
- Image displaying ratio: step-less magnification which can be increased. Real-time local zooming held
- Maximum storage of more than 100,000 images. Images recorders optional
- Case history created and created automatically
- Images manage system, Case history database system and diagnosis & measurement pre-treat system
Technical Specification:
Display 14 inch high-resolution monitor
Scanning mode Electronic linear array, electronic convex linear
Display mode B, B/B, B/M, M, 4B
Magnification ×1.0, ×1.2, ×1.5, ×2.0
Gray Scale 256 level
Displaying depth 240mm, and depth could be increased and stepless
magnified
Resolution Horizontal: ≤2mm Vertical: ≤1mm
Geometrical precision ≤5%
Blind area ≤3mm
TGC 8-section TGC adjust
Image Polarity left/right turn, positive /negative turn and
up / down turn
Cineloop successive 256 frames
Output Interface two output interfaces, VGA and PAL video signal
output
Power Supply Range AC 110V 60Hz AC 220V 50Hz
Focusing modes dynamic-emitting focus, dynamic-receiving focus,
dynamic aperture, adaptive acoustic lens
Output interface AV, S-video, VGA
USB connector Yes
Measurement and Analysis Software:
- The General Measurement and Analysis
- The Measurement and Analysis for Gynecology
- The Measurement and Analysis for Obstetrics
- The Measurement and Analysis for Urology
- The Measurement and Analysis for Small parts
- The Measurement and Analysis for Heart and the ambient vessels
Remarks: for each picture there are more than 5 parameters for reference, such as distance, area, perimeter, angle, volume, gestational age, fetus’ weight, heart rate, slope rate, flux, left ventricle and so on
Standard Configuration:
- Main unit
- 14 inch monitor
- 256-frame cineloop
- Images permanent image storage
- Two probe connectors
- USB port
- 3.5MHz electronic convex transducer (2.5/5.0MHz)
Optional:
- Electronic transvaginal transducer (5.0/7.5MHz)
- Electronic High-frequency linear transducer (6.5/8.5MHz)
- MSF: Mass storage
- Jet printer, laser printer, video printer
- DICOM 3.0 interface