Feature:<UL>
Pure sine wave AC output, wide application range
High frequency design, low power consumption, high transfer efficiency, long backup time
CPU control technology, on-load standby and mute function
Superior start-up ability to start the load directly
Perfect protection: overload, short-circuit, over-voltage, under-voltage over temperature protection
Low noise (<30dB), aluminum alloy shell, strong anti-interference ability, low radiation
Auto-recharged function</ul>
Specification:
Pure sine wave AC output, wide application range
High frequency design, low power consumption, high transfer efficiency, long backup time
CPU control technology, on-load standby and mute function
Superior start-up ability to start the load directly
Perfect protection: overload, short-circuit, over-voltage, under-voltage over temperature protection
Low noise (<30dB), aluminum alloy shell, strong anti-interference ability, low radiation
Auto-recharged function</ul>
Specification:
Model
|
HP-J30101
|
HP-J50101
|
HP-J60102
|
|
Capacity(W)
|
300W
|
500W
|
600W
|
|
Input
|
Voltage range
|
100VAC±5V ~ 260VAC±5V
|
||
|
Frequency
|
50/60Hz±10%(automatic identification)
|
||
Output
|
Voltage(Mains Mode)
|
100VAC±5V ~ 260VAC±5V
|
||
|
Voltage(INV Mode)
|
100VAC±5V ~ 260VAC±5V
|
||
|
Frequency(INV Mode)
|
50/60±2.5Hz
|
||
|
Waveform
|
Sine wave
|
||
|
Transfer Time
|
10-15ms
|
||
|
Load Type
|
Printer and computer
|
||
|
Overload Capability
|
110%, the system will be shut down
automatically within 60s
|
||
Efficiency
|
Mains Mode
|
98%
|
||
|
INV Mode
|
80%
|
||
Battery
|
Type
|
VRLA battery
|
||
|
Input DC Voltage
|
12VDC/24/VDC
|
||
|
Discharge Voltage
|
9.6-9.8VDC
|
||
|
Charging Current
|
6A-10A
|
||
|
Charging Time
|
8h≥90%
|
||
|
Floating Voltage
|
13.9VDC±0.2V
|
||
|
Over-Discharge Voltage
|
14.5V
|
||
|
Automatic Charging
|
Be charged automatically
when inverter is shut down
|
||
|
Input Voltage range
|
100VAC±5V ~ 260VAC±5V
|
||
Display
|
LED Display
|
Mains mode/INV mode/Charge mode/fault
|
||
|
Warning Function
|
Overload/short circuit/under voltage
|
||
Protection
|
Spike&Surge
|
Yes
|
||
|
Over Voltage/Under Voltage
|
Switch to INV mode when mains input is out of range
|
||
|
Overload
|
When up to110%, it will ring the alarm bell
and the system will be protected within 30s.
|
||
|
Short Circuit
|
Protection and alarm bell
|
||
Environment
|
Acoustic Noise
|
≤40dB(1 meter)
|
||
|
Storage temp.
|
0-40℃
|
||
|
Humidity
|
20% to 90%
|
||
|
Altitude
|
≤1500M
|
||
|
DC Voltage
|
12VDC/24VDC
|
||
Dimensions D×W×H(mm)
|
260×230×71
|