Product Main

Specifications

Feature
 
* PF>0.98@230VAC                                      
* EMI meets EN55022(CISPR22) Class B
* Low power consumption
* Approvals: UL/CUL/TUV/CB/CE
* Forced air cooling by built-in DC fan
* Built-in remote sense function
* Built-in remote ON/OFF control
* Can adjust from 20% to 100% output voltage by external control 1V to 5V
* Protections: Over load / Over voltage /Over temp/ Short circuit
* 100% Full load high temperature burn-in test
* 2 years warranty
Description 
Input voltage range                             180-260VAC
Input frequency                                    47-63HZ
Inrush current                                      Cold Start, 15A/115VAC,30A/230VAC
Output adjustment range                   ± 3% rated output range by potential meter
Line regulation:                                    ≤0.5%
Output over-load protection               105%-135% Hiccup mode, auto-recovery
Output over voltage protection           115%-145% Rated output voltage
Output short circuit protection            Hiccup mode, auto –recovery
Rise, hold up time                               50mS, 20mS at full load (typical)
Hi-pot isolation                                     I/P-O/P: 3KVAC,I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Operating temperature range           0℃ to +40℃@100%,-10℃@80%,+60℃@60% load
Storage temperature range               -40℃ to +85℃,0 to 95%RH(Non-condensing)
Safety standards                                  UL60950-1
EMC standards                                     EN55022 class B, EN61000-3-2.3
                                                                 EN61000-4-2,3,4,5,6,8,11,ENV50204
Cooling method                                   Free air cooling convection 
Weight                                                    1.08 kg/pc