1.Range:up to 35m
2.Temp:-40C to +250C
3.Pressure:-0.1 to +4.0Mpa
4.Accurancy:less than 0.1%
2.Temp:-40C to +250C
3.Pressure:-0.1 to +4.0Mpa
4.Accurancy:less than 0.1%
VRWKRD54 Pulse Radar Level Transmitter:
Advantages:
Non-contact measurement
Simple mounting Wear and maintenance-free Unaffected by pressure, temperature, gas and vapour High measuring accuracy SIL qualified
Function:
Extremely short microwave pulses are emitted via the antenna system to the measured product, reflected by the product surface and received again by the antenna system. The time from emission to reception of the signals is proportional to the level. A special evaluation procedure ensures a reliable and precise measurement.
|
VRWKRD54 Pulse Radar Level Transmitter:
Advantages:
Non-contact measurement
Simple mounting Wear and maintenance-free Unaffected by pressure, temperature, gas and vapour High measuring accuracy SIL qualified
Function:
Extremely short microwave pulses are emitted via the antenna system to the measured product, reflected by the product surface and received again by the antenna system. The time from emission to reception of the signals is proportional to the level. A special evaluation procedure ensures a reliable and precise measurement.
FEATURES:
Output versions: 2 wire compact transmitter with 4…20 mA and HART communication
Adjustment programming: With local display/programmer module, remote HART programming
Mounting: On top of the tank. Non-contact measurement with wave stick or horn antenna
Housing material: Aluminum cast
Material of wetted parts: Stainless steel, PTFE, PP
Operating principle: Level, volume and weight measurement calculated from distance between the sensing point and the surface
Ex approval: Yes
APPLICATION CONSIDERATIONS:
Suggested applications: Large tanks with high pressure and extreme temperatures
Measurable mediums: Electrically conductive or non-conductive (liquids, free-flowing solids) materials with min. ε>1.5 dielectric constant
Advantages: High accuracy.
Special applications: High pressure, high temperature applications
Application restrictions: Liquid hydrogen, helium and ammonia cannot be measured
TECHNICAL DATA:
Power supply: 24 V DC,
Ambient temperature:-20…+55°C
Medium temperature:-60…+250 °C flange temp.
Process pressure: ax. 64 bar
Measuring range: 40 m (100 m)
Accuracy: ± 1 mm, ± 10 mm
Output: 4…20 mA / HART
Process connection: Flange
Ingress protection: IP67
|