Product Main

Specifications

Feature
 
* AC input range selectable by switch
* Low cost, high reliability                              
* Low power consumption
* Built-in EMI filter
* Protections: Over load / Short circuit
* 100% Full load high temperature burn-in test
* 1 year warranty
Description 
Input voltage range                         90-132VAC/180-264VAC selectable by switch
Input frequency                                47-63HZ
Inrush current                                  Cold Start, 25A/115VAC, 50A/230VAC
Output adjustment range              ± 10% rated output voltage
Line regulation:                               ≤0.5%
Output over-load protection          105%-135% Hiccup mode, auto-recovery
Output short circuit protection      Hiccup mode, auto recovery
Rise, hold up time                         100mS, 20mS at full load (typical)
Hi-pot isolation                               I/P-O/P,I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC 
Operating temperature range      0℃ to +50℃@100%,-10℃@80%,+60℃@60% load
Storage temperature range         -40℃ to +85℃,0 to 95%RH(Non-condensing)
Safety standards                            Design refer to UL1012  Design refer to FCC part 15J
Cooling method                             Free air cooling convection 
Weight                                              0.93kg/pc