Product Main

Specifications

 
Feature
 
* AC input range selectablt by switch               
* Low cost, high reliability
* Low power consumption
* Built-in EMI filter
* Protections: Over load / Short circuit
* 100% Full load high temperature burn-in test
* 1 year warranty
Description 
Input voltage range                       85-132VAC,170-264VAC selectable by switch
Input frequency                              47-63HZ
Inrush current                                 Cold Start,20A/115VAC,40A/230VAC
Output adjustment range             CH1: - 5% ~+10% rated output range voltage
 Line regulation                             ≤0.5%
Output over-load protection         105%-150% Fold back current limiting, auto-recovery
Output short circuit protection     Fold back current limiting, auto-recovery
Rise, hold up time                        100mS, 20mS at full load (typical)
Hi-pot isolation                               I/P-O/P: 3KVAC,I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Operating temperature range     0℃ to +50℃@100%,-10℃@80%,+60℃@60% load
Storage temperature range        -40℃ to +85℃,0 to 95%RH(Non-condensing)
Safety standards                            Design refer to UL 1012
EMC standards                              Design refer to FCC part 15J
Cooling method                             Free air cooling convection