Product Main

Quick Details

Brand Name: FORESIGHT
discharge current: 0-300A
current measurement resolution: 0.1A
discharge voltage range: 20v-60vdc
voltage measurement resolution: 0.5% 0.01V
Model Number: FST-CT48
Place of Origin: China (Mainland)
String voltage monitoirng range: 0-60v
discharge voltage range: 20-60vdc
voltage measurement resolution: 0.01v
current measurement resolution: 0.1A
Weight: <13kg
Communication port: USB Port
Constant current discharge range: 0-300A
Cell voltage type: 1.2V/2V/6V/12V
Battery type: NICD and Lead acid battery

Specifications

General:

Batteries in power plants, transformer substations, Telecom company and Force communications must provide the equipment they serve with standby power in the event of a power failure. Unfortunately, however the capacity of such Batteries can drop significantly for a number of reasons before their Calculated life expectancy is reached. this is why so important to check Batteries regular intervals, and the only reliable way of measuring battery Capacity is to conduct a discharge test.


1,Used to discharge to battery String removed from the system

2,Discharge to Battery string voltage as 24V/48V, Cell voltage as 1.2V/2V/6V/12V

3,4 adjustable stop points and multiple alarm Designs to control the discharge process intelligently

4,7inch LCD touch screen for easy operation and Showing various parameters real time

5,Support real time monitoring by PC orSD CardDownload data after discharge

6,PC software for capacity evaluation and Report generation


48vdc 0300A battery discharge tester battery load bankbattery load tester with PC monitoring and cell voltage monitor

1,on-line monitoring test Setting interface:


battery discharge tester 48V 1450Amp

Online monitoring for battery string: When the battery pack is under the state of online discharge, uniform charge and floating charge, perform real-time online monitoring for all cells. the Monitoring includes string voltage, cell voltage, charge/discharge current, Monitoring time of battery string, charge/discharge capacity of battery string and etc.

 

1,Discharge test setting Interface:

battery discharge tester 48V 1450Amp

Perform Discharge of constant current taking advantage of intellectualized dummy load after the battery pack is removed from system, set up the parameters of " discharge current", " discharge time ", " discharge capacity", " final protective voltage of whole pack" and" final protective voltage of cell", and the tester could Carry out discharge function automatically, display discharge current, battery discharged capacity, the whole pack voltage, Cell voltage, discharge time and etc at real time; 

1,

Battery String voltage Is 24V/48V and single battery voltage is 2V/6V/12V. Users can decide how to set Single battery voltage

2,When we do confirmation test We can set four condition of stopping discharging: Stop voltage of Whole set battery; Single battery voltage stop; Stop discharging Time;Discharging Voltage

3,Easy to operate: All input Is simple  English menu, humanized Operation, clear procedure, every step and interface will give user brief tips Avoid incorrect operation fundamentally

battery discharge tester 48V 1450Amp


1,Mature correspondence Function, including USB communication port and SD card connection port. Data Will be transferred to PC begin the storage management. It can analyze and Store historical data in long time; It's convenient, reliable and safe if we Transfer data via SD card

2,Tester host Integrated monitoring part and power part together, and power part adopted Latest hi-efficiency components

Providing Data management, print, analyze, count report, automatic generate test report. Amplify or minify the voltage curve for easy observation

battery discharge tester 48V 1450Amp

1,the auto-test and protection Function: during test if we find whole battery set or single battery have any Problem test will stop automatically to avoid any further damage and completely Prevent shock on the device; test can be cut off according to actual condition as well

2,after test all test result Will be displayed automatically and according to these data advise maintenance Point

Technical Specifications: (Take 48V/100A and 48V/150A,48V 300A as sample)

Features

Specifications

Model

  48V/100A

  48V/150A

48V/300A

String Voltage Measurement range

060V

String Voltage Resolution

0.01V

Voltage measurement Accuracy

0.5%

Cell Voltage Resolution

0.01V

 Discharge current Range

1100Amps

1150Amps

1-300Amps

2060V

Current Measurement Resolutions

0.1A

Cell voltage Measurement type

1.2V/2V: 0-4V; 6V:0-8V; 12V: 0-15V

Power Supply

110VAC or 220VAC15%   50Hz/60Hz

Air Cooling

Communication Mode

USB Communication port and SD Card storage

Display

7inch Touch screen

High-Voltage Insulation test

Input-the Enclosure:2200Vdc 1min

Input-Output:2200Vdc 1min

Output- the enclosure:700Vdc 1min

Safety Standard

EN610950

CE Certificate

LVD: EN61010-12010; EMC:EN61326-1:2013

Work Temperature

-550

Storage Temperature

-4070

Humidity

Relative humidity 090%(402)

Noise

<60dB

Dimensions of Host Machine

405x225x265mm

405x225x265mm

355x230x440mm

 

Dimensions of Package

 506*403*406mm

 506*403*406mm

600x400x500mm

Net Weight

<10.5Kg

<10.5Kg

<13Kg

Gross Weight

24kg

24kg

34kg