Brand Name: | FORESIGHT |
---|---|
discharge current: | 0-300A |
current measurement resolution: | 0.1A |
discharge voltage range: | 20v-60vdc |
voltage measurement resolution: | 0.5% 0.01V |
Model Number: | FST-CT48 |
Place of Origin: | China (Mainland) |
String voltage monitoirng range: | 0-60v |
discharge voltage range: | 20-60vdc |
voltage measurement resolution: | 0.01v |
current measurement resolution: | 0.1A |
Weight: | <13kg |
Communication port: | USB Port |
Constant current discharge range: | 0-300A |
Cell voltage type: | 1.2V/2V/6V/12V |
Battery type: | NICD and Lead acid battery |
Quick Details
Specifications
General:
Batteries in power plants, transformer substations, Telecom company and Force communications must provide the equipment they serve with standby power in the event of a power failure. Unfortunately, however the capacity of such Batteries can drop significantly for a number of reasons before their Calculated life expectancy is reached. this is why so important to check Batteries regular intervals, and the only reliable way of measuring battery Capacity is to conduct a discharge test.
1,Used to discharge to battery String removed from the system
2,Discharge to Battery string voltage as 24V/48V, Cell voltage as 1.2V/2V/6V/12V
3,4 adjustable stop points and multiple alarm Designs to control the discharge process intelligently
4,7inch LCD touch screen for easy operation and Showing various parameters real time
5,Support real time monitoring by PC orSD CardDownload data after discharge
6,PC software for capacity evaluation and Report generation
1,on-line monitoring test Setting interface:
Online monitoring for battery string: When the battery pack is under the state of online discharge, uniform charge and floating charge, perform real-time online monitoring for all cells. the Monitoring includes string voltage, cell voltage, charge/discharge current, Monitoring time of battery string, charge/discharge capacity of battery string and etc.
1,Discharge test setting Interface:
Perform Discharge of constant current taking advantage of intellectualized dummy load after the battery pack is removed from system, set up the parameters of " discharge current", " discharge time ", " discharge capacity", " final protective voltage of whole pack" and" final protective voltage of cell", and the tester could Carry out discharge function automatically, display discharge current, battery discharged capacity, the whole pack voltage, Cell voltage, discharge time and etc at real time;
1,
Battery String voltage Is 24V/48V and single battery voltage is 2V/6V/12V. Users can decide how to set Single battery voltage
2,When we do confirmation test We can set four condition of stopping discharging: Stop voltage of Whole set battery; Single battery voltage stop; Stop discharging Time;Discharging Voltage
3,Easy to operate: All input
Is simple English menu, humanized
Operation, clear procedure, every step and interface will give user brief tips
Avoid incorrect operation fundamentally
1,Mature correspondence Function, including USB communication port and SD card connection port. Data Will be transferred to PC begin the storage management. It can analyze and Store historical data in long time; It's convenient, reliable and safe if we Transfer data via SD card
2,Tester host Integrated monitoring part and power part together, and power part adopted Latest hi-efficiency components
Providing Data management, print, analyze, count report, automatic generate test report. Amplify or minify the voltage curve for easy observation1,the auto-test and protection Function: during test if we find whole battery set or single battery have any Problem test will stop automatically to avoid any further damage and completely Prevent shock on the device; test can be cut off according to actual condition as well
2,after test all test result Will be displayed automatically and according to these data advise maintenance Point
Technical Specifications: (Take 48V/100A and 48V/150A,48V 300A as sample)
Features |
Specifications | |||||
Model |
48V/100A |
48V/150A |
48V/300A | |||
String Voltage Measurement range |
060V | |||||
String Voltage Resolution |
0.01V | |||||
Voltage measurement Accuracy |
0.5% | |||||
Cell Voltage Resolution |
0.01V | |||||
Discharge current Range |
1100Amps |
1150Amps |
1-300Amps | |||
|
2060V | |||||
Current Measurement Resolutions |
0.1A | |||||
Cell voltage Measurement type |
1.2V/2V: 0-4V; 6V:0-8V; 12V: 0-15V | |||||
Power Supply |
110VAC or 220VAC15% 50Hz/60Hz | |||||
|
Air Cooling | |||||
Communication Mode |
USB Communication port and SD Card storage | |||||
Display |
7inch Touch screen | |||||
High-Voltage Insulation test |
Input-the Enclosure:2200Vdc 1min Input-Output:2200Vdc 1min Output- the enclosure:700Vdc 1min | |||||
Safety Standard |
EN610950 | |||||
CE Certificate |
LVD: EN61010-12010; EMC:EN61326-1:2013 | |||||
Work Temperature |
-550 | |||||
Storage Temperature |
-4070 | |||||
Humidity |
Relative humidity 090%(402) | |||||
Noise |
<60dB | |||||
Dimensions of Host Machine |
405x225x265mm |
405x225x265mm |
355x230x440mm
| |||
Dimensions of Package |
506*403*406mm |
506*403*406mm |
600x400x500mm | |||
Net Weight |
<10.5Kg |
<10.5Kg |
<13Kg | |||
Gross Weight |
24kg |
24kg |
34kg | |||