EVTS-500V300A   EV/HEV/PHEV Battery Testing System  
Equipment Model : EVTS-500V300A Battery Testing Equipment       Equipment Item Code: CE-6001W-500V300A
Project index
Parameter index
Input Power
AC 380V ±10% 50Hz
resolution
14bit
Single-phase power
65KW
Single-phase current
296A
Input Power
195KW
Voltage
Per Channel Voltage Range
Charge: 25V~500V; Discharge: 25V~500V
Accuracy
± 1% of range(Full-scale)
Stability
± 1% of range(Full-scale)
Current
Per Channel Current Range
Charge: 15A~300A; Discharge: 15A~300A
Accuracy
± 1% of range(Full-scale)
Stability
± 15% of range(Full-scale)
Power
Per Channel Output Power
150KW
Stability
± 2% of range(Full-scale)
Time
Current Response Time
The Current gets to 300A Hardware Response Time is 1s
Step Time Range
Single Step Time Range≤365*24 h,
Time Form Support 00: 00: 00(h, min, s)
Auxiliary Channel
Type of Auxiliary Channel
Test&Control Temperature &Voltage of unit cell (max with 248 auxiliary channels)
Temperature Range
﹣25℃~110℃
Temperature Stability
±(1% of reading + 1℃)
Temperature Resolution
0.1℃
Voltage Range
10 mV~5V
Voltage Stability
± 0.1% of full range
Data Recording
Record Condition
Time△t: (1s ~60000s)
Voltage△U: (25V~500V)
Current△I: (15A~300A)
Record Frequency
1Hz
Charge
Charge Mode
Constant Current Charge, Constant Voltage Charge,
Constant Current and Constant Voltage Charge
End Conditon
Main channel: Voltage, Current, Relative Time, Capacity
Auxiliary channel: Temperature , Voltage
Discharge
Discharge Mode
Constant Current Discharge, Constant Power Discharge
End Condition
Main channel: Voltage, Current, Relative Time, Capacity
Auxiliary channel: Temperature , Voltage
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
254
Nested Loop
Nested loop Function, Max Support 3 Layers
Protection
Software Protection
l            Power-down Data Protection; NULL
l            Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
Characters of channel
4-wire connecting
Energy feedback
Discharge energy feed back to power grid
Mode of channel control
Control independently
Noise
<85dB
Data base
Use MySQL data base to manage testing data centralizely
Communication way of host computer
Based on TCP/IP protocol
Data Output
EXCEL, TXT, Graph
Communication Interface
net port
Per Unit Main Channels No.
1
Temperature Auxiliary channel with each main channel
optional
Voltage Auxiliary channel with each main channel
optional
Dimensions
W*D*H: 1350*733*1800 (mm)
 
Equipment Working Environment
Project index
Parameter index
Working Temperature Range
0℃~40℃
Storage Temperature Range
-10℃~50℃
Working Environment Relative Humidity Range
≤ 70% RH ( no coagulation of vapor)
Storage Environment Relative Humidity Range
≤ 80% RH ( no coagulation of vapor)
 
Picture for Reference Only, take the material object as the standard.