Product Main

Specifications

Offer aidu ADUK-2B resistivity imaging survey system,high density resistivity survey,IP resistivity system,induced polarization measurement,resistivity imaging survey,high density electrical measurement,IP earth resistivity meter,resistivity and IP imaging, multipole imaging system,hydrogeologicalmeter,electrical resistivity tomography, electrical imaging,geoelectric imaging,mining detector,mineral prospecting equipment etc.


We are one of the largest  professional and reliable  manufacturers of  geophysical prospecting instrument in China,supply various geophysical instrument, resistivity meter, resistivity IP and SP system, resistivity, IP, SP, TEM survey, magnetometer, logging systerm,seismograph, gravity meter, proton magnetometer, water detector,mineral prospector,drilling equipment, logging system and element analyzer etc.

ADUK-2B resistivity imaging survey system main applications:
Main engineering exploration like railway, bridge, warehouse, residence, freeway, airport, dyke and geological disasters etc., water detection in coal goaf, archeological and mineral prospecting and so on.
 
Main features: 
Assemble data acquiring part and multiple channel conversion switches into one box, it doesn't only reduce volume and weight, but also avoid the mistakes caused by parameters setting inconsistency as operate host and switch separately.
With all functions of high density electrical prospecting system and general electrical prospecting.
Add big small currency switch shift and input impedance change shift to increase weak signal acquiring ability;
Boost the 500VDC limit of voltage supply and improve anti-jamming ability;  
Add the storage and output functions of compensation SP voltage value;
Apply 16 bytes A/D and D/A to improve the distinguishing ability to data acquiring; 
Add the function of auto-detecting earthing resistance before each measurement, and give indication to the point exceeds earthing resistance value; if you want to continue the measurement then it will carry out automatically. Use fixed symbol to replace the point value so that you can eliminate the point in data processing;
  
Main specifications:
Measured voltage range: 6V 
Measured voltage resolution: 1μV
Measured currency accuracy: 1%
Polarization measurement: ≤3%±0.2; 3%±0.1
SP compensation range: 1000mV 
Electrode number: 60 channel 
Max. voltage supply: 500 VDC 
Memory capacity: 1MB
Power source: 1~2 nodes 1# batteries or out connected 12V battery (when use battery then please take batteries out)