A Series Technical Parameters of Hot Water Boiler: |
Item |
Unit |
LIP20-A1 |
LIP24-A1 |
LIP20-A2 |
LIP24-A2 |
Input power |
kW |
20 |
24 |
20 |
24 |
Output power |
kW |
18 |
22 |
18 |
22 |
Heating efficiency |
η |
﹥91% |
﹥91% |
﹥91% |
﹥91% |
Energy efficiency grade |
class |
2 |
2 |
2 |
2 |
Electric power used |
V/Hz/w |
~220/50/125 |
Degree of protection |
IP |
x4D |
Gas type used |
Natural gas |
Natural gas |
Gas pressure |
pa |
2000 |
Reference gas consumption |
m3 |
0.05-0.1/kw/h |
Reference heating area |
m2 |
﹤140 |
﹤180 |
﹤140 |
﹤180 |
Outlet water temperature of heating |
0C |
Floor heating 30-60;Radiator 30-80 |
Temperature backlash of heating |
K |
10~30 |
Hot water temperature |
0C |
30~60 |
Minimum activation pressure of hot water |
bar |
0.3 |
Minimum usage flow volume of hot water |
Kg/min |
2.5 |
Capacity of hot water(△T=25℃) |
Kg/min |
10 |
12 |
10 |
12 |
Applicable pressure of hot water |
bar |
0.5~6 |
Applicable pressure of heating system |
bar |
0.5~2.5 |
Protection pressure of heating system |
bar |
3 |
Pump head |
m |
5 |
Expansion tank volume |
L |
6.5 |
Expansion tank pressure |
bar |
1.1 |
Pipe connector |
G" |
Heating 3/4;Hot water 1/2 ;Fuel gas3/4 |
Smoking tube diameter |
Φ |
coaxial 60/100 |
Total weight |
Kg |
34 |
35 |
35 |
36 |
Outer sizes(HeightxWidthxThickness) |
mm |
740x400x306 |