Product Main

Specifications

Summary:
Used for testing Cable sheath and insulating materials’ Flame-retardance, high-temperature- resistance when the cable-core reaches 204℃ . then put it in the flame of some strength and time.
Standard: MT818-200 in Coal Industry

Technical parameters:
1. Size of Burning box: 1100(W)*500(D)*900mm(H)
2. Size of electric cabinet: 1100(W)*500(D)*400mm(H)
3. Size of Load box: 400(W)*600(D)*1000mm(H)
4. Load current: 10~3000A, adjustable
5. Angle of Flame blower: 90°, inner diameter: ¢9.5mm; meterial: H62 rass
6. Height of flame: inner flame: 75±5mm; outer flame: 125±10mm
7. Thermodetector: with Buzzer prompting when temperature reaches 204±2℃, equipped with K type thermocouple 0~1200℃
8. Ignition device :automatic High-pressure electronic ignition
9. Rang of burning time : 0.01~99.99S
10. Last time : 1~9999S, attached with a last- time stop button
11. Exhausting device: can be opened manually after testing
12. Weight: 300kg
13. Power: control box: Voltage: AC220V, Current: 2A
         load cases: Voltage: two-phase 380V, Current: 48A