Specification
|
NO
|
Items
|
Specs
|
|
1
|
Sizes and weight
|
86x63x48;250g
|
|
2
|
Dimension of inlet
|
13.8mm
|
|
3
|
Dimension of outlet
|
13.3mm
|
|
4
|
Driving method
|
Brushless, Magnetic , 2 phase or 3 phase
|
|
5
|
Pump material
|
PA66+GF30% (optional)
|
|
6
|
Condition of use
|
Continuously
|
|
7
|
Fluids
|
Water, oil, gasoline, acid and alkali solution etc
|
|
8
|
Max working temp
|
60(2 phase)or 100(3 phase)
|
|
9
|
Power consumption
|
3.25W~28.8W
|
|
10
|
Rated voltage
|
12V or 24Vdc
|
|
11
|
Voltage used
|
5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc
|
|
12
|
Max rated current
|
1.2A
|
|
13
|
Max flow rate
|
12L/MIN(3.2G/MIN)
|
|
14
|
Max Static Head
|
6.0m(19.4ft)
|
|
15
|
Noise
|
<35dB
|
|
16
|
Water proof class
|
IP68(can be submersible installed)
|
|
17
|
Life span
|
More than 30000hrs
|
|
18
|
Power supply
|
Solar panel; DC electric source; battery
|
Features
1,Brushless, permanent magnetic rotor, maintenance-free, long life
2,small size, high efficiency, low consumption, low noise
3,Ceramic sleeve and ceramic shaft optional
4,Stator and circuit board sealed by epoxy resin, completely water proof
5,Parameter adjustable, 12v pump’s head can be 2m to 4.5m..
6,Can be customized
Difference between 2-phase and 3-phase sensor less BLDC pump
|
2-Phase
|
u Driven by sensor which should be put inside the pump body
|
|
3-Phase
|
u Driven by program, sensor less, whole control circuit can be put outside
u Speed adjustable by PWM, analog signals(0-5v) or potentiometeroptional
u Locked-rotor and reverse connection protection
u Automatic overload protection and over-temperature protection
u Soft start with low in-rush current, great for PV panel
|
|
model
|
voltage
|
Rated current
|
head
|
flow
|
power
|
|||
|
V
|
A
|
m
|
ft
|
L/H
|
G/H
|
w
|
||
|
DC40A-0510
|
5
|
0.65
|
1.0
|
3.5
|
320
|
85
|
3.25
|
|
|
DC40A-0615
|
6
|
0.70
|
1.5
|
4.9
|
380
|
100
|
4.20
|
|
|
DC40A-0930
|
9
|
1.20
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
|
DC40A-1220
|
12
|
0.53
|
2.0
|
6.5
|
450
|
120
|
6.36
|
|
|
DC40A-1230
|
12
|
0.90
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
|
DC40A-1240
|
12
|
1.10
|
4.0
|
13
|
650
|
172
|
13.2
|
|
|
DC40A-1245
|
12
|
1.20
|
4.5
|
14.6
|
680
|
180
|
14.4
|
|
|
DC40A-2430
|
24
|
0.45
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
|
DC40A-2440
|
24
|
0.55
|
4.0
|
13
|
650
|
172
|
13.2
|
|
|
DC40A-2450
|
24
|
0.80
|
5.0
|
16.2
|
690
|
182
|
19.2
|
|
|
DC40A-2460
|
24
|
1.20
|
6.0
|
19.4
|
720
|
190
|
28.8
|
|
|
Remarks
|
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.
|
|||||||
Parameters (The technical specification only for reference, it can be customized)
|
model
|
voltage
|
Rated current
|
head
|
flow
|
power
|
|||
|
V
|
A
|
m
|
ft
|
L/H
|
G/H
|
w
|
||
|
DC40A-0510
|
5
|
0.65
|
1.0
|
3.5
|
320
|
85
|
3.25
|
|
|
DC40A-0615
|
6
|
0.70
|
1.5
|
4.9
|
380
|
100
|
4.20
|
|
|
DC40A-0930
|
9
|
1.20
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
|
DC40A-1220
|
12
|
0.53
|
2.0
|
6.5
|
450
|
120
|
6.36
|
|
|
DC40A-1230
|
12
|
0.90
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
|
DC40A-1240
|
12
|
1.10
|
4.0
|
13
|
650
|
172
|
13.2
|
|
|
DC40A-1245
|
12
|
1.20
|
4.5
|
14.6
|
680
|
180
|
14.4
|
|
|
DC40A-2430
|
24
|
0.45
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
|
DC40A-2440
|
24
|
0.55
|
4.0
|
13
|
650
|
172
|
13.2
|
|
|
DC40A-2450
|
24
|
0.80
|
5.0
|
16.2
|
690
|
182
|
19.2
|
|
|
DC40A-2460
|
24
|
1.20
|
6.0
|
19.4
|
720
|
190
|
28.8
|
|
|
Remarks
|
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.
|
|||||||