Product Main

Specifications

Specification
NO
Items
Specs
1
Sizes and weight
51x34x42.7; 50g
2
Dimension of inlet
Optional (10mm or 8mm or 6mm)
3
Dimension of outlet
Optional (8mm or 5mm or 6mm)
4
Driving method 
Brushless, Permanent Magnetic , 2 phase
5
Pump material
ABS+PC(optional)
6
Condition of use
Continuously 
7
Fluids 
Water, oil, gasoline, acid and alkali solution etc
8
Max working temp
60 Celsius 
9
Power consumption
0.5W~4.2W
10
Rated voltage
12Vdc
11
Voltage used
4.5Vdc ~ 12Vdc
12
Max rated current
350mA
13
Max flow rate
4L/MIN(1.06G/MIN)
14
Max Static Head
3m(9.8ft)
15
Noise
<40dB(most 35dB)
16
Water proof class
IP68(can be submersible installed)
17
Life span
More than 30000hrs
18
Power supply
Solar panel; DC electric source; battery 
Features
1,Brushless, permanent magnetic rotor, maintenance-free, long life
2,small size, high efficiency, low consumption, low noise
3,Stator  and circuit board sealed by epoxy resin, completely water proof
4,Parameter adjustable, 12v pump’s head can be 1.5m to 3m..
5,Can be fixed on the vessel wall with sucking disk
6,Can be customized
Model Note
DC30A-XX YY
 
1,DC--------means the pump is brushless dc pump
2,30---------Sizes: 30 means the size is at the range of 3cm 
3,A---------differentiate outlet and inlet from DC30
4,XX--------voltage :12 means the voltage is 12Vdc
5,YY---------Head: 30 means the pump head is 3m
 
Parameters (The technical specification only for reference, it can be customized)
Model
Voltage
Rated Current
Max flow
Max water head
Power
V
A
L/H 
G/H
ft
w
DC30A-0406
4.5
0.10
100
26
0.6
2.0
0.45
DC30A-0507
5
0.11
110
29
0.7
2.3
0.55
DC30A-0609
6
0.11
120
32
0.9
3.0
0.66
DC30A-0712
7
0.13
160
42
1.2
3.1
0.91
DC30A-0913
9
0.14
170
42
1.3
4.2
1.26
DC30A-1215
12
0.18
200
53
1.5
4.8
2.16
DC30A-1219
12
0.22
210
55
1.9
6.2
2.64
DC30A-1223
12
0.23
220
58
2.3
7.5
2.76
DC30A-1225
12
0.26
230
61
2.5
8.1
3.12
DC30A-1227
12
0.29
235
62
2.7
8.8
3.48
DC30A-1230
12
0.35
240
63
3.0
9.7
4.20
Remarks
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.