Model Note
DC40A-XX YY
1,DC--------means the pump is brushless dc pump
2,40---------Sizes: 40 means the size is at the range of 4cm
3,A---------differentiate outlet and inlet from DC40
4,XX--------voltage :12 means the voltage is 12Vdc
5,YY---------Head: 30 means the pump head is 3m
model
|
voltage
|
Rated current
|
head
|
flow
|
power
|
|||
V
|
A
|
m
|
ft
|
L/H
|
G/H
|
w
|
||
DC40A-0510
|
5
|
0.65
|
1.0
|
3.5
|
320
|
85
|
3.25
|
|
DC40A-0615
|
6
|
0.70
|
1.5
|
4.9
|
380
|
100
|
4.20
|
|
DC40A-0930
|
9
|
1.20
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
DC40A-1220
|
12
|
0.53
|
2.0
|
6.5
|
450
|
120
|
6.36
|
|
DC40A-1230
|
12
|
0.90
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
DC40A-1240
|
12
|
1.10
|
4.0
|
13
|
650
|
172
|
13.2
|
|
DC40A-1245
|
12
|
1.20
|
4.5
|
14.6
|
680
|
180
|
14.4
|
|
DC40A-2430
|
24
|
0.45
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
DC40A-2440
|
24
|
0.55
|
4.0
|
13
|
650
|
172
|
13.2
|
|
DC40A-2450
|
24
|
0.80
|
5.0
|
16.2
|
690
|
182
|
19.2
|
|
DC40A-2460
|
24
|
1.20
|
6.0
|
19.4
|
720
|
190
|
28.8
|
|
Remarks
|
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.
|
Parameters (The technical specification only for reference, it can be customized)
model
|
voltage
|
Rated current
|
head
|
flow
|
power
|
|||
V
|
A
|
m
|
ft
|
L/H
|
G/H
|
w
|
||
DC40A-0510
|
5
|
0.65
|
1.0
|
3.5
|
320
|
85
|
3.25
|
|
DC40A-0615
|
6
|
0.70
|
1.5
|
4.9
|
380
|
100
|
4.20
|
|
DC40A-0930
|
9
|
1.20
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
DC40A-1220
|
12
|
0.53
|
2.0
|
6.5
|
450
|
120
|
6.36
|
|
DC40A-1230
|
12
|
0.90
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
DC40A-1240
|
12
|
1.10
|
4.0
|
13
|
650
|
172
|
13.2
|
|
DC40A-1245
|
12
|
1.20
|
4.5
|
14.6
|
680
|
180
|
14.4
|
|
DC40A-2430
|
24
|
0.45
|
3.0
|
9.7
|
530
|
140
|
10.8
|
|
DC40A-2440
|
24
|
0.55
|
4.0
|
13
|
650
|
172
|
13.2
|
|
DC40A-2450
|
24
|
0.80
|
5.0
|
16.2
|
690
|
182
|
19.2
|
|
DC40A-2460
|
24
|
1.20
|
6.0
|
19.4
|
720
|
190
|
28.8
|
|
Remarks
|
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.
|