Specification
NO
|
Items
|
Specs
|
1
|
Sizes and weight
|
71.9x59.5x43;250g
|
2
|
Dimension of inlet
|
13.8mm
|
3
|
Dimension of outlet
|
10mm
|
4
|
Driving method
|
Brushless, Magnetic , 2 phase or 3 phase
|
5
|
Pump material
|
PA66+GF30% (optional)
|
6
|
Condition of use
|
Continuously
|
7
|
Fluids
|
Water, oil, gasoline, acid and alkali solution etc
|
8
|
Max working temp
|
60degree(2 phase)or 100degree(3 phase)
|
9
|
Power consumption
|
2.5W~15.6W
|
10
|
Rated voltage
|
12Vdc or 24Vdc
|
11
|
Voltage used
|
5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc
|
12
|
Max rated current
|
1A
|
13
|
Max flow rate
|
9L/MIN(2.4G/MIN)
|
14
|
Max Static Head
|
5m(16ft)
|
15
|
Noise
|
<35dB
|
16
|
Water proof class
|
IP68(can be submersible installed)
|
17
|
Life span
|
More than 30000hrs
|
18
|
Power supply
|
Solar panel; DC electric source; battery
|
Features
l Brushless, permanent magnetic rotor, maintenance-free, long life
l small size, high efficiency, low consumption, low noise
l Ceramic sleeve and ceramic shaft [optional]
l Stator and circuit board sealed by epoxy resin, completely water proof
l Parameter adjustable, 12v pump’s head can be 2m to 4m..
l Can be customized
Difference between 2-phase and 3-phase sensor less BLDC pump
2-Phase
|
u Driven by sensor which should be put inside the pump body
|
3-Phase
|
u Driven by program, sensor less, whole control circuit can be put outside
u Speed adjustable by PWM, analog signals(0-5v) or potentiometer[optional]
u Locked-rotor and reverse connection protection
u Automatic overload protection and over-temperature protection
u Soft start with low in-rush current, great for PV panel
|
Model Note
DC40B-XX YY
1,DC--------means the pump is brushless dc pump
2,40---------Sizes: 40 means the size is at the range of 4cm
3,B---------differentiate outlet and inlet from DC40
4,XX--------voltage :12 means the voltage is 12Vdc
5,YY---------Head: 30 means the pump head is 3m
Parameters (The technical specification only for reference, it can be customized)
model
|
voltage
|
Rated current
|
head
|
flow
|
power
|
||
V
|
A
|
m
|
ft
|
L/H
|
G/H
|
w
|
|
DC40B-0510
|
5
|
0.5
|
1.0
|
3.5
|
250
|
66
|
2.5
|
DC40B-0615
|
6
|
0.6
|
1.5
|
4.9
|
300
|
79
|
3.6
|
DC40B-0935
|
9
|
0.87
|
3.5
|
11.4
|
420
|
122
|
8.0
|
DC40B-1220
|
12
|
0.45
|
2.0
|
6.5
|
350
|
93
|
5.4
|
DC40B-1230
|
12
|
0.70
|
3.0
|
9.7
|
400
|
106
|
8.4
|
DC40B-1240
|
12
|
1.00
|
4.0
|
13.0
|
460
|
122
|
12.0
|
DC40B-2430
|
24
|
0.35
|
3.0
|
9.7
|
400
|
106
|
8.40
|
DC40B-2440
|
24
|
0.50
|
4.0
|
13.0
|
460
|
127
|
12.0
|
DC40B-2450
|
24
|
0.65
|
5.0
|
16.0
|
520
|
148
|
15.6
|
Remarks
|
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.
|