Product Main

Specifications

Specification
NO
Items
Specs
1
Sizes and weight
80x64.4x48;250g
2
Dimension of inlet
13.2mm(1/4 inch thread)
3
Dimension of outlet
13.2mm(1/4 inch thread)
4
Driving method 
Brushless, Magnetic , 2 phase or 3 phase
5
Pump material
PA66+GF30% (optional)
6
Condition of use
Continuously 
7
Fluids 
Water, oil, gasoline, acid and alkali solution etc
8
Max working temp
60degree(2 phase) or 100degree(3 phase)
9
Power consumption
2.5W~26.4W
10
Rated voltage
12Vdc or 24Vdc
11
Voltage used
5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc
12
Max rated current
1.2A
13
Max flow rate
10.5L/MIN(2.7G/MIN)
14
Max Static Head
7m(26ft)
15
Noise
<35dB
16
Water proof class
IP68(can be submersible installed)
17
Life span
More than 30000hrs
18
Power supply
Solar panel; DC electric source; battery 
Features
l Brushless, permanent magnetic rotor, maintenance-free, long life
l small size, high efficiency, low consumption, low noise
l Ceramic sleeve and ceramic shaft [optional]
l Stator and circuit board sealed by epoxy resin, completely water proof
l Parameter adjustable, 12v pump’s head can be 2m to 5m..
l Can be customized
Difference between 2-phase and 3-phase sensor less BLDC pump
2-Phase
u Driven by sensor which should be put inside the pump body
3-Phase
u Driven by program, sensor less, whole control circuit can be put outside
u Speed adjustable by PWM, analog signals(0-5v) or potentiometer[optional]
u Locked-rotor and reverse connection protection
u Automatic overload protection and over-temperature protection
u Soft start with low in-rush current, great for PV panel
Model Note
DC40E-XX YY
 
1,DC--------means the pump is brushless dc pump
2,40---------Sizes: 40 means the size is at the range of 4cm 
3,E---------differentiate outlet and inlet from DC40
4,XX--------voltage :12 means the voltage is 12Vdc
5,YY---------Head: 30 means the pump head is 3m
 
Parameters (The technical specification only for reference, it can be customized)
model
voltage
Rated current
head
flow
power
V
A
m
ft
L/H
G/H
w
DC40E-1250
12
1.10
5.0
16.0
500
132
13.2
DC40E-2470
24
1.10
7.0
23.0
620
164
26.4
Remarks
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.