Coating Thickness Gauge (ACT280)
Coating Thickness Gauge Features
● Two measuring methods: magnetic induction (F) and eddycurrent (N)
● 2 measurement modes: continuous / single
● 5 types of probes can be used (F400, F1, F10, N1, CN02,);
● 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
● 5 statistic values: mean value(MEAN), max. value(MAX), min. value(MIN), numbers of measuring(NO.), standard
deviation(S.DEV);
● Direct testing mode and block statistics mode (APPL/BATCH)
● Direct print out of statistical values
● Low battery indication
● 2 switch off modes: manual and auto
● The instrument caters for the demands as follows:GB/T 4956─1985 GB/T 4957─1985 JB/T 8393─1996 JJG 889─95 JJG 818─93
● Application fields : Electroplating industry, Spray-painting and plastic-painting industry ,Aluminum processing industry, Pipeline industry,
Car manufacture industry Steel construction and color steel plate industry
● The ACT280 dataview software with USB interface is in the standard delivery for the customer
Coating Thickness Gauge Features
● Two measuring methods: magnetic induction (F) and eddycurrent (N)
● 2 measurement modes: continuous / single
● 5 types of probes can be used (F400, F1, F10, N1, CN02,);
● 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
● 5 statistic values: mean value(MEAN), max. value(MAX), min. value(MIN), numbers of measuring(NO.), standard
deviation(S.DEV);
● Direct testing mode and block statistics mode (APPL/BATCH)
● Direct print out of statistical values
● Low battery indication
● 2 switch off modes: manual and auto
● The instrument caters for the demands as follows:GB/T 4956─1985 GB/T 4957─1985 JB/T 8393─1996 JJG 889─95 JJG 818─93
● Application fields : Electroplating industry, Spray-painting and plastic-painting industry ,Aluminum processing industry, Pipeline industry,
Car manufacture industry Steel construction and color steel plate industry
● The ACT280 dataview software with USB interface is in the standard delivery for the customer
Standard Configuration
| Name |
Quantity
|
|
ACT280
|
1
|
|
Probe
|
1
|
|
Standard test plate
|
5
|
|
Substrate
|
1
|
|
Carrying Case
|
1
|
|
Operation Manual
|
1
|
Optional Accessorie
| Designation |
Model
|
|
Probes
|
F400, F1, F10, N1, CN02
|
Technical Speciffcations
|
Measuring range |
Refer to the table below
|
|
Probes available
|
|
|
Tolerance
|
|
|
Minimum resolution:
|
|
|
Measuring condition
|
|
|
Operation language
|
English
|
|
Standards
|
DIN, ISO, ASTM,BS
|
|
Calibration
|
Zero and foil calibration
|
|
Statistics
|
Number of measurements, mean, standard deviation,maximum and minimum of 3000 readings |
|
Data memory
|
495 readings
|
|
Humidity:
|
20%~90%RH
|
|
Environment of application:
|
0-40℃ (No strong magnetic field)
|
|
power supply
|
2×1.5V AA
|
|
Dimensions
|
1250mm×67 mm×31 mm
|
|
Weight
|
400g
|
Optional probes and technical specification
|
Probe model
|
F400
|
F1
|
F1/90°
|
F5
|
F10
|
|||
|
Operating principle
|
Magnetic induction
|
|||||||
|
Measuring range (mm)
|
0~400
|
0~1250
|
0~5000
|
0~10000
|
||||
|
Low range resolution(mm)
|
0.1
|
0.1
|
1
|
10
|
||||
|
Accuracy
|
One-point calibration (mm)
|
±(3%H+1)
|
±(3%H+5)
|
±(3%H+10)
|
||||
|
Two-point calibration (mm)
|
±((1~3)%H+0.7)
|
±((1~3)%H+1)
|
±((1~3)%H+5)
|
±((1~3)%H+10)
|
||||
|
Measuring conditions
|
Min curvature radius (mm)
|
Convex
|
1
|
1.5
|
Flatten
|
5
|
10
|
|
|
Diameter of the min area (mm)
|
F3
|
F7
|
F7
|
F20
|
F40
|
|||
|
Critical thickness of substrate (mm)
|
0.2
|
0.5
|
0.5
|
1
|
2
|
|||
|
Probe model
|
N400
|
N1
|
N1/90°
|
CN02
|
N10
|
||||
|
Operating principle
|
Eddy current
|
||||||||
|
Measuring range (mm)
|
0~400
(Chrome on copper |
0~1250
0~40) |
10~200
|
0~10000
|
|||||
|
Low range resolution(mm)
|
0.1
|
0.1
|
1
|
10
|
|||||
|
Accuracy
|
One-point calibration (mm)
|
±(3%H+0.7)
|
±(3%H+1.5)
|
±(3%H+1)
|
±(3%H+25)
|
||||
|
Two-point calibration (mm)
|
±[(1~3)%H+0.7]
|
±[(1~3)%H+1.5]
|
___
|
±[(1~3)%H+25]
|
|||||
|
Measuring conditions
|
Min curvature radius (mm)
|
Convex
|
1.5
|
3
|
Flatten
|
Only flatten
|
25
|
||
|
Diameter of the min area (mm)
|
F4
|
F5
|
F5
|
F7
|
F50
|
||||
|
Critical thickness of substrate (mm)
|
0.3
|
0.3
|
0.3
|
No limit
|
50mm aluminum foil |
||||