Product Main

Specifications

Specification for Mobile camping room
 
House characteristics:
1, adopting the corrugated steel sheets to weld the outside; house framework is welded of various H type steel, slot steel, the angle steel ; having the performance that solid & pressurized, defending rain, snow and sandstorm.
2. Adopting EPS, PU, rock cotton etc., which are the heat insulation, sound insulation and fireproofing materials. It’s used with air condition machine to attain heat preservation in winter and defending hot in summer.
3. Following human physical engineering science to design the reasonable indoor space and features size.
4. Following customer's requirements to install electric circuit, water road, warm air pipeline, the correspondence circuit, solar energy lighting keeping warm etc, and provide complete sets of overload protection of the leakage, fire alarm, explosion-proof electrical and so on.
5. Following customer's requirements to supply every kind of indoor facilities. 

NO
Items
Data
1
Overall Size
Length:9100±5mm;Width3000±5mm;Height:4050±5mm;(or design as to customer's requirements)
2
Welding Quality
firm welding,formation,without weld beading,weld penetration,blister and so on. Remove coating & polish brightly after welding
3
Coating Quality
bright & uniform paint coating, smooth and not sagging, clear font and good adhesion and weather resistance, invariant color
4
Home Features
make it as per customer's requirement, reasonable settings, fixed solidly and firmly
5
water-resistant & sealing properties
6—8mm/min Experimental shower does not leak
6
Heating performance
In the ambient temperature of -40 °C, the room temperature will reach up to 15 °C in 2 hours
7
Refrigeration Performance
In the ambient temperature of -40 °C, the room temperature will lower down to 28 °C in 2 hours
8
wiring
With indoor residual current switch, power cord is orderly alignment. When the wire goes through the metal structures point, there should be insulating loop or liner. Reliable connection is between electricity facilities and room body with outdoor grounding bolt-hole
9
Ground Resistance
≤3 ohm
10
Cold insulation resistance
Air relative humidity is 45-75% and ambient temperature is 15-35 °C.When the voltage is less than 500V, the cold insulation resistance of every electrical circuit to earth and to each other in AC electrical system must not be less than 6 megohm