Product Main

Quick Details

Place of Origin:
Brand Name:
Model Number:
Model: Finesorb-3050

Specifications

1.Outfitting Samples

Pretreatment of the coal sample is accurately

weighed and quickly into the model Sample

 weight: about 2kg Industrial analysis implements

 in accordance with GB/T2121991 of Coal

Sample Industrial Analysis Method
 
2.Air Tightness Inspection
2.1 Air Inflation

Filled with Helium to system, the pressure is

higher than highest pressure 1MPa of
Isothermal Adsorption Experiment.

System temperature is adjusted to reservoir

temperature. Continuous observation for

the system seal condition, if good, go to next

experiment.
3. Free Space Volume Measurement
3.1 Temperature

System temperature is adjusted to reservoir

temperature. 
3.2 Inflation

Open the cylinder, inflate He gas to system,

adjust standard pressure valve, and then close

the standard room valve        
3.3 Data Acquisition
Open the valve of standard room and sample
cylinder, collect the data after the balance of
presssure, do the volume experiment twice,
allowable error  is ±0.1cm3

3.4 Calculate the coal volume and get the blank

volume of sample room
4. Isothermal Adsorption Experiment
4.1 Ensure Experiment Pressure

The highest experimental pressure is set up to 1.2

times of  reservoir pressure,minimun pressure is 8MPa

4.2 Experiment Pressure Spot Distribution
Highest Pressur<8MPa, choose 6 experiment spots;

Highest Pressure between8MPa-12MPa, choose 7

experiment spots;
Highest Pressure>12MPa, choose 8 experiment spots
4.3 Inflation

Open regulated valve and standard room valve,inflate

methane to system,and adjust the standard room

pressure to ideal pressure.
4.4 Data Collection

After get the ideal pressure and stable temperature,

start  the data collection of the  isothermal adsorption

experiment program
4.5 Ensure Time of Adsorption Balance
More than 12 hours at least

4.6 Repeat 

step 3 -5, until the end
of experiment o flast pressure spot

Technique parameter
Basic feature
Single or multiple component isothermal adsorption and desorption
Temperature: room temperature~ 100℃
Operation pressure: 40MPa
System maximum pressure: 70MPa
 
Sample Cylinder, Reference Cylinder
 
Sample Particle Size
≤60um
Sample Weight
200g
Reference Cylinder Volume
150ml
Reference Cylinder Quantities
6pcs OD: 70mm Length: 330mm
Sampler Cylinder Volume
150ml
Material
Stainless Steel
Pressure Seal
Specified Metal Ring Seal
Stressor
Gas Booster Pump
Pressure Device
Air Compressor
Thermostat
 
Oil Bath pan
60L*2pcs
Oil Bath pan Size
50cm(length)*48cm(width)*24cm(depth)
Temperature Setting
Independent Zones
Oil Bath pan Circulation
Internal Installation
Constant Temperature Oil
BYOD
Pressure Acquisition
 
Pressure Sensor 
Three Wire Pressure Sensor
Pressure Range
 0-40MPa
Rated Pressure
40MPa
One-piece Barometer
Precision±0.1%
Quantity
12pcs
Output
 3mv/v
Temperature Acquisition
 
Temperature Detection System
Temperature Sensor±0.1℃
Multi-channel Digital Converter Precision
16
Gas source
 
Aggregate Supply
3
Gas Input
Methane,Helium,Carbon Dioxide
Pressure
20MPa
Stability
3%
Electric Gas Regulator
 
Aggregate Supply
3
Pressure
40MPa
Stability
1%
Input
 0-10v
Booster Pressure
 0.6Mpa
Computer Control
 
Computer
Basic Frequency0.3GHZ,
Internal Storage1GB, Hard Disk 160GB
Auto Control
Computer
System Software
FINESORB-ISO Data Acquisition Software
FINESORB-ISO Absorb/Desorb Data Processing Software
Multicomponent Gas Absorb/Desorb Data Processing softer ware
Chinese specification provided