Description:
Aperture size(mm) : 3, 5, 7
Typical Fields of Application:
MarkingMarking-on-the-fly
Laser display
Laser therapy
Science and research
|
Benefits
highest speed and accuracy
high torque low drift compact and tight structure dust-proof, interference-proof easy to install effective heat-sinking system |
Applications
Marking
Marking-on-the-fly Laser display Laser therapy Science and research |
S-8107 is available for sale as a 2D module without housing. The module can be used by OEM customers to integrate into their own systems and constists of 2 galvos, 2 driver boards and XY Mount.
|
Aperture size, mm
|
3
|
5
|
7
|
|
|
Max. laser power, W
|
Nd:YAG@1064 nm
|
n/a
|
n/a
|
<100
|
|
CO2
|
n/a
|
n/a
|
<50
|
|
|
Small step response time, ms
|
0.15
|
|||
|
Tracking error, ms
|
0.1
|
|||
|
Marking speed, mm/s
|
n/a
|
n/a
|
4000
|
|
|
Positioning speed, mm/s
|
n/a
|
n/a
|
15000
|
|
|
Writing speed , cps
|
good quality
|
n/a
|
n/a
|
1000
|
|
high quality
|
n/a
|
n/a
|
800
|
|
|
Zero drift
|
15 μRad/℃
|
|||
|
Scale drift
|
50 ppm/℃
|
|||
|
Long-term drift over 8 hours
|
<0.6 mrad
|
|||
|
Max. scan angle
|
±12°
|
|||
|
Linearity
|
99.90%
|
|||
|
Repeatability
|
8 μRad
|
|||
|
Input Signals
|
XY2-100 or Analog ±5V, ±10V
|
|||
|
Operating temperature
|
25℃±10℃
|
|||
|
Input power
|
±24 V
|
|||
|
Max. RMS current
|
2 A
|
|||
|
Peak current
|
10 A
|
|||
|
Weight (without cable)
|
-
|
|||
All angles are in mechanical degrees.
All above specifications are applicable after 60 sec warm-up.
All above specifications are applicable after 60 sec warm-up.