Product Main

Specifications

Application

It is suitable for power department, measuring department, quality control department, research units, and institutions of higher
learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive
power compensation device and the production of enterprise etc.


Type:
GF303 program-controlled three-phase standard power source,

GF303H program-controlled three-phase standard power source (industrial control model)


Main functions and features

1. To set up and take the load regulation of voltage, current, phase angle , frequency and power factor etc;

2. To set 2 ~ 128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output;

3. Frequency points is adjustable (AB and phase C);

4. Voltage, current output a wide range, big power, high stability, waveform distortion degree is small;

5. Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is
higher than 0.01%;

6. To apply the 32 bit MPU + DSP + FPGA, powerful flexible;

7.To use hardware PID, fast response, the change of load will not cause output volatility;

8. Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output
waveform, the harmonic output precision, harmonic distortion degree is small;

9.  Range switching automatically

10. To use software calibration, simple operation, stable and reliable;

11.To have big screen, 320 x 240 LCD display, Chinese or English interface, operating simplely;

12. To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically;

13. With RS232 interface, and PC connection

14. To take place machine software, it can be output through the PC software program;


Technical Data
AC voltage output

Range: 57.7 V ,100 V , 220 V , 380 V; range switch automatically

Adjust fineness: 0.01% RG

Accuracy: 0.05% RG

Stability: 0.005% RG / 200 s

Distortion degree: <0.1% (not capacitive load)

Output power: 25 VA

Full load regulation rate: 0.01% RG

Full load regulation time: less than 1 mS

Long-term stability: ± 60 PPM/year

AC current output

Range: 0.1, 0.25 A , 0.5, 1 A , 5 A ,10 A , 20 A; range switch automatically

Adjust fineness: 0.01% RG

Accuracy: 0.05% RG

Stability: 0.005% RG / 200 s

Distortion degree:< 0.1% (not capacitive load)

Output power: 25 VA

Full load regulation rate: 0.01% RG

Full load regulation time: less than 1 mS

Long-term stability: ± 60 PPM/year

Power output
Accuracy: 0.05% RG

Stability: 0.005% RG / 200 s

Phase angle

Adjusting range: 0 ~ 359.999°

Resolution: 0.001°
Accuracy: 0.03° 
Frequency

Adjusting range: 40 Hz ~ 65 Hz

Resolution: 0.002 Hz

Accuracy: 0.002 Hz
Temperature drift:  ± 0.5 PPM / ℃

Long-term stability: ± 4 PPM/year

Power factor

Adjusting range:-1 ~ 0 ~ + 1;

Resolution: 0.0001;

Accuracy: 0.0005.
Harmonic accuracy

Harmonic phase: 0 ~ 359.99°

Harmonic phase accuracy: < 0.01°

Harmonic set accuracy: 0.1% (relative to the base wave ratings)

With capacitive load capacity:
0 ~ 280 V: 1 uF

280 ~ 420 V: 0.6 uF

Work power supply:

AC 220 V ± 10%, frequency 50 Hz

Environmental conditions:

1. Working temperature: 0 ℃ ~ 40 ℃;

2. Relative humidity: ≤ 85% ;

3. Storage condition:-30 ℃ ~ 60 ℃

Volume and weight:

Size: 450 mm x 380 mm x 160 mm;

Weight:  18 kg.