Crane Parts, Remote Control
mechanical handling
highly robust pendant control stations
safety requirements of IEC stardard
Crane Parts, Remote Control
mechanical handling
highly robust pendant control stations
safety requirements of IEC stardard
Crane Parts, Remote Control
Environment
|
||
Conforming to standards
|
|
IEC 947-5-1, EN 60947-5-1
|
Approvals
|
|
NEMKO, Special version: UL Listed A600-Q600, CSA A600-Q600
|
Protective treatment
|
|
Standard Version: TH TH
|
Ambient air temperature
|
|
Operation: -25.+70 Storage:-40+70
-25.+70 -40+70
|
Vibration resistance
|
|
15 gn (10.500 HZ) conforming to IEC 68-2-6
|
Shock resistance
|
|
100 gn conforming to IEC 68-2-27
|
Electric shock protection
|
|
Class conforming to IEC 536 and NF C 20-030
|
Degree of protection
|
|
IP65 conforming to IEC 529; IK 08 conforming to EN 50102
|
Mechanical durability
|
Op
cycles
|
1 million
|
Enclosure
|
|
Double insulated polypropylene, colored yellow throughout
|
Cable entry
|
|
Rubber sleeve with stepped entry diameter for cable
826mm
|
|
||
Rated operational characteristics
|
|
ZB2-BE, XEN-G XAC-S
~~AC-15: A600 or Ue=600V,Ie=1.2A or Ue=240V,Ie=3A
=DC-13: Q600 or Ue=600V, Ie=0.1A or Ue=250V, Ie=0.27A
XEN-T
~~AC-15: A300 or Ue=240V, Ie=3A
=DC-13: Q300 or Ue=250V, Ie=0.27A
conforming to IME 947-5-1 Appendix A
|
Thermal current (Ithe)
|
A
|
10
|
Rated insulation voltage (Ui)
|
V
|
ZB2-BE, XEN-G XAC-S :600 Degree of pollution 3
XEN-T 400 Degree of pollution 3
Conforming to IEC 947-1
|
Rated impulse withstand voltage
(u imp)
|
Kv
|
6 conforming to IEC 947-1
|
Positive operation
|
|
Mushroom head pushbutton: N/C contact with positive opening to IEC 947-5-1 Section 3
|
Contact operation
|
|
N/C or N/O slow break
|
Resistance across terminals
|
mΩ
|
≤25
|
Operating force
|
N
|
Operations
- with 1 N/O contact: 10
- with 1 N/C contact: 8
- with additional N/O contact: +5
- with additional N/O contact: +3
|
Terminal referencing
|
|
Conforming to CENELEC EN 50013
|
Short-circuit protection
|
|
10 A cartridge fuse type gG (gl)
|
Cabling
|
mm2
|
Screw and captive cable clamp terminal Capacity: min 1 x 0.5 max with or without cable end: 2 x 1.5 or 1 x 2.5 mm2, 6.3mm Faston connectors (on request),
|