Product Main

Specifications

Summary:
Standard: IEC6 0695-2-10  ~IEC6 0695-2-13 (GB/T5169.10-2006~GB/T5169.13-2006), “Glow wire/hot wire basic test methods, glow wire testing equipment and general test method, etc”, UL 746A, EC829 DIN695, and VDE0471
Applicable scope: lighting equipment, low-voltage apparatus, household appliances, machine tool electric appliance, electrical machine, electric-power tool, electronic instrument, eletrotechnical instrument, information technological equipment, Electrical affairs equipment and so on.

Technical parameters:
1. Diameter of the glowing filament: 4mm ± 0.04mm Ni/Cr(80/20), 500W Special standard circular, Horizontal stalling
2. Diameter of the thermocouple: 0.5mm K type, imported insulation type with high temperature-resistance armoured thermocouple; heat-resisting of the armour: 1250 ℃(better than 1050℃)
3. Glow wire electricity heating temperature: 500 ℃~ 1120 ℃(digital readout, can be preset), temperature fluctuation: < 3 ℃
4. Pressure the experimental article can hold to the glowing filament: 1.0N±0.1N(adjustable, better than 1.0N±0.2N), max depth: 7mm± 0.5mm(adjustable)
5. Experimental article moving speed: 10mm/s~ 25mm /s
6. Testing time: 30s±0.1s, (1s~ 999.9s, digital readout, can be preset)
7. Thickness of standarf Foil piece: 0.06mm, purity: ≥99.8%, equipped with a metering
8. Thickness of Ignites matting board: 10mm, The white board: 12g /m²~ 30g /mm ², Standard silk paper: 200mm ± 5mm under the glowing filament
9. Experimental volume: ≥ 0.5m ³, background: black, background illumination: ≤ 20Lux
10. Overall dimension: 1220mm(W)*600mm(D)*1250mm(H), kicker port: 100mm
11. power: 1kVA, 220V, 50-60Hz