Product Main

Specifications

Summary:
Used for testing and ensuring the storage and use adaptability of the electrical, electronics and automobile electric appliances, etc. products .It’s been used in schools, factories, searching departments, etc. units.

Tester structure:
(1) Tester body: Use the numerical control machine to make it shaped, whose style is elegant. And it use the no-reaction handle, which is easy to operate.
(2) Inner of the tester: Use the imported high-quality stainless steel (SUS304).
(3) Outer of the tester: Use the A3 steel plastic spraying, which increases the texture and cleanliness.
(4) Huge observing windows: Keep the inner tester bright with attached lights, and use the thermode builtin toughened glass, so that you can observe the inside situation clearly at any time.
(5) Equipped with a testhole whose diameter is 50mm, to make use for external testing power wire or holding wire.
Control system:
(1) Temperature control: use Japan RKC Digital display touch buttons, touching set, digital and direct display. Temperature control and output power are all by P.I.D microcomputer calculus, to achieve high-accuracy, high- efficiency electricity benefit. If something goes wrong, it will alarm. (can chose imported programmable control instrument and printer in addition)
(2) Refrigerator: Use the French original "taikang" totally-closed compressor.
(3) dry filter, refrigerant flow Windows, repair valve, oil separator, solenoid valve, and surge drum are all use the imported original pieces
(4) Refrigeration system: Use the design of unit or binary-type low temperature loop system
(5) Use the multi-wing air feeder feeding air, to avoid any dead space, and can make uniform temperature distribution in the test area.
(6) Heating, and cooling system are fully independent, which can improve the efficiency, reduce the cost, increase the using life and reduce the failure.
(7) Have the protections of leakage, and operation instructions. And it will automatically stop after failure warning.
Standard: GB 2423.1—2001, GB 2423.2—2001, GB 10592—89, GJB150.3-86, GJB150.4-86

Technical parameters:
1. Working size
working volume
working size
100L
400*500*500
150L
500*600*500
225L
500*600*750
500L
700*800*900
800L
800*1000*1000
1000L
1000*1000*1000
1300L
1000*1000*1300
 
2. Temperature: 0℃-150℃  -20℃-150℃  -40℃-150℃  -60℃-150℃  -70℃-150℃
3. Temperature fluctuation: ±0.5℃(unloaded)
4. Temperature deviation: ≤±2℃.
5. Average ramp rate: 0.7℃~1.0℃/min(unloaded)
6. Time-setting range: 0~9999H
7. Power: AC380V