Product Main

Specifications

IEC BVV Power Cable

1; Voltage rating:U0/U 450/750V, copper or aluminum core
2; ISO9001-2008, CCC, IEC
3; factory direct sales.

1, cables used for communication system, its rated voltage should be at least equal to the system of nominal voltage, in dc system, nominal voltage should not greater than 1.5 times of rated voltage, and System allows more than nominal voltage working voltage by 10%.
2, cables long-term allowed no more than 70 degrees Celsius temperature, BV - 90 shall not exceed 90 degrees Celsius; the installation should not below 0 Celsius temperature.
3, cable permissible min. bending radius: less than 25 mm of exterior cable should be no less than 4 times of cable diameter, if for 25 millimeters, wire bending radius should not less than 6 times of cable diameter. ,
4, wire and cable length of knitting or into the dish for 100 meters, length error of 0.5 meters
5, RV - 90 long-term allowed no more than 90 degrees Celsius temperature
Type
Name
Laying place and requirement
Crated
voltage
Nominal
Section
(mm2)
227IEC01(BV)
Copper conductor PVC insulated wires
Aluminum conductor PVC insulated wires
Fixed laid indoors
Conduit etc.
450/750
300/500
450/750
1.5...185
227IEC05 (BV)
0.5...1
BLV
2.5...185
227IEC07(BV-90)
Heat resistant copper conductor PVC insulated wire at 90 0C
Mainly be laid at the places of high temperature environment and can be laid indoors, conduits.
300/500
0.5...2.5
BVR
Copper conductor PVC insulated flexible cable
Be for laying permanent place where flexible required.
450/750
2.5...150
BLVV
Aluminum conductor PVC insulated PVC sheathed round wires
Fixed laid, fit for the places with high mechanical protection and moisture place, can be laid in the air or underground.
 
 
BVVB
Copper conductor PVC insulated PVC sheathed flat wires
300/500
1...10
BLVVB
Aluminum conductor PVC insulated PVC sheathed flat wires
300/500
2.5...10
227IEC02(RV)
227IEC06(RV)
Copper conductor PVC insulated flexible connector wire
Mainly used at middle and light style moving electronics, home appliances, power and lighting and the places where flexible required
450/750
300/500
1.5...240
0.3...1
227IEC42(RVB)
Copper conductor PVC insulated flat flexible connector wire
300/300
0.3...1.5
 
RVS
 
Copper conductor PVC insulated flexible twisting connector wire
300/300
0.3...1.5
227IEC52(RVV)
227IEC53(RVV)
Copper conductor PVC insulated PVC sheathed round flexible connector wire
300/300
300/500
0.5...6
0.3...4
 
227IEC08(RV-90)
 
Cu conductor heat resistant PVC insulated flexible connector wire at 90 0C
Mainly used at the places where heat resistance is required
300/500
0.5...2.5