Medical Syringe Pump Features:
- Three kinds of modes: rate mode, time mode, body weight mode
- Double CPU, making the process of injection safer and more reliable
- Accurate and sensitive pressure sensor detecting occlusion pressure accurately.
- Injection time, dose, solution can be checked during the process of injection.
- Precision step motor. There is no pulsating wave even during low-rate injection.
- KVO rate can be selectable according to concrete requirements from 0.1ml/h to 5ml/h
- Excellent injection operation. The accuracy will be ensured even at small volume injection
- Accept all standard syringes of 5ml, 10ml, 20ml, 30ml and 50ml. It will self-diagnose and display the syringe size and set parameter automatically in the form of menu.
- Alarm is given when there is malfunction or operation error, and the machine stops running automatically.
- Save the preset volume automatically when there is unpredictable switch off, ensuring the accuracy of injection volume
Specifications:
- Applicable syringes: All brands of standard syringes: 5ml, 10ml, 20ml, 30ml, 50ml
- Accuracy: +/-2%
- Injection rate: 5ml: 0.1ml/h-100ml/h
10ml: 0.1ml/h-200ml/h
20ml: 0.1ml/h-400ml/h
30ml: 0.1ml/h-600ml/h
50ml: 0.1ml/h-1500ml/h
- Accumulated injection volume: 0.1ml-9999.9ml
- Modes of operation: selectable: rate mode, time mode, body weight mode
- Time mode: volume limit: 0.1~999.9ml, time: 1~2000minutes
- Body weight mode:
Drug limit: 0.1~999.9mg
Solution limit: 0.1~999.9ml
Weight: 0.1~300.0kg
Dose: 0.1~9999.9mg/kg/h, ug/kg/min
- Displayed information: rate, volume limit, accumulated injection volume, syringe size, pressure value, battery capacity, unit of medical dosage, bed No., AC power indicator, battery charge indicator, drug name, bolus rate
- Alarm functions: Over, near, occlusion, low battery, syringe disengaged, no AC power supply, serious low battery
- KVO rate: 0.1ml/h~5.0ml/h (selectable)
- Bolus rate:
5ml: 100ml/h
10m: 200ml/h
20ml: 400ml/h
30ml: 400ml~600ml/h
50ml: 400ml~1500ml/h
- Power supply: AC100-240V, 50/60Hz
- Fuse: T2AL250V
- Maximum power consumption: 25W can run for 4 hours after being recharged
- Battery: rechargeable lithium polymer battery, 7.4V, 1600mAh
- Battery recharge: When the pump is connected to the AC power supply, turn on the power and the battery will automatically recharge( about 8-14 hours to recharge fully).
- Electrical safety: comply with the stipulation of IEC60601-1:1996
- Electromagnetic compatibility: comply with the stipulation of IEC60601-1-2:2006
- Shell material: ABS plastic
- Classification: classII, Type BF
- Operating conditions: environment temperature 5℃~40℃, air pressure 80KPa~106Kpa, relative humidity≤80%
- Storage conditions: environment temperature -40℃~55℃, air pressure 50KPa~106Kpa, relative humidity≤95%
- Applied standards: IEC60601-1:2005
IEC60601-2-24:1998
IEC60601-1-2:2006
ISO780-1997
ISO15223:2000
ISO7886-1:1993
ISO/IEC: Guide No.37
<Consumer Goods Usage Instructions>
- Weight: <3.0kg
- Dimension: 380*190*180mm (length*width*height)