Product Main

Specifications

Switching power supply
1.Low price and high reliability
2.105 output capacitor
3.AC input power suitable for the world
4.High efficiency and low operation temperature
5.Soft-start current can reduce the AC input impact effectively
6.With short-circuit and overload protection
7.Compact size, light weight
8.100% full-load burning test
9.Installed with EMI filter, minimum wave
Model
Specification
S-100-3
S-100-5
S-100-7.5     
S-100-12
S-100-15
S-100-24
S-100-27
S-100-48
DC output voltage
3V
5V
7.5V
12V
15V
24V
27V
48V
Output voltage error (Note2)
±2%
±2%
±1%
±1%
±1%
±1%
±1%
±1%
Rated output current
20A
20A
13.6A
8.5A
6.7A
4.5A
3.7A
2A
Output current rage
0-20A
0-20A
0-13.6A
0-8.5A
0-6.7A
0-4.5A
0-3.7A
0-2A
Wave and noise(Note3)
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note4)
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
Load stability(Note5)
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
DC output power
60W
100W
102W
102W
100.5W
108W
99.9W
96W
Efficiency
70%
78%
80%
81%
81%
84%
84%
84%
Adjustable range for DC voltage
2.85-3.3V
4.75-5.5V
6.75-8.25V
10.8-13.2V
13.5-16.5V
21.6-26.4V
26-32V
43.2-52.8V
AC input voltage range
85132VAC/180264VACselected by switch4763Hz;255-370VDC
Input current
2.4A/115V 1.2A/230V
AC impulse current
Cold-start current 30A/115V 60A/230V
Leakage current
<1mA/240VAC
Overload protection
105%150% TypePULSING HICCUP SHUTDOWN Reset: auto recovery
Over-voltage protection
 
High-temperature protection
 
Temperature coefficient
±0.03%(050)
Setup rise hold up time
200ms,100ms,30ms
Vibration
10500Hz,2G 10min./1cycle,Period for 60min,Each axes
Withstand voltage
Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC
Isolation resistance
Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms
Working temperature and humidity
-10+60,20%90%RH
Store temperature and humidity
-20+85,10%95RH
Overall dimension
199*98*38mm
Weight
0.5Kgs
Safety standards
Meet UL 1012 requirement(Not apply for the mark)
EMC standards
Meet FCC Part 15J Conduction Class B
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.