| Brand Name: | zoanco |
|---|---|
| color: | red |
| Executive standard: | ce |
| Operating Voltage: | 24 |
| Product name: | manual call point |
| Model Number: | sb106 |
| Place of Origin: | China (Mainland) |
| Material: | ABS |
| Working pressure: | 9-32VDC Volts |
| Size: | W89mm ,H93mm, D26mm |
| Type: | manual call point |
| Operating Voltage Range: | 9-32VDC Volts |
| Nominal Operating Resistance: | 300ohm |
| Relay Contact Ratings: | 2A/30VDC |
| Operating Humidity Range: | 95% RH, Non-condensing |
| Colour/Case Material: | Red/ ABS |
Quick Details
Specifications
Skype firealarm87 /wechat 15220176087
Specifications
Operating Voltage Range: 932VDC Volts
Nominal Operating Resistance: 300
Relay Contact Ratings: 2A/30VDC
Operating Humidity Range: 95% RH, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: W89mm,H93mm, D26mm
Base Dimensions: W87mm,H87mm, D31.5mm
Weight: Net Weight 125g (with base)
Colour/Case Material: Red/ ABS
INSTALLATION
this manual should be left with the owner/user of this equipment.
the call points should be installed in a position where they will not be subjected to mechanical stresses, and
Where the temperature is within the operating temperature range.
Areas where there are, or are likely to be, aggressive substances should be avoided.
to ACTIVATE ALARM
the conventional manual call point designed for conventional fire alarm system for reporting fire or emergency
Condition by its button latches. the call point has one 300 ohm resistor is used on the PCB board between
Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed.

Specifications
Operating Voltage Range: 932VDC Volts
Nominal Operating Resistance: 300
Relay Contact Ratings: 2A/30VDC
Operating Humidity Range: 95% RH, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: W89mm,H93mm, D26mm
Base Dimensions: W87mm,H87mm, D31.5mm
Weight: Net Weight 125g (with base)
Colour/Case Material: Red/ ABS
INSTALLATION
this manual should be left with the owner/user of this equipment.
the call points should be installed in a position where they will not be subjected to mechanical stresses, and
Where the temperature is within the operating temperature range.
Areas where there are, or are likely to be, aggressive substances should be avoided.
to ACTIVATE ALARM
the conventional manual call point designed for conventional fire alarm system for reporting fire or emergency
Condition by its button latches. the call point has one 300 ohm resistor is used on the PCB board between
Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed.