Product Main

Specifications

Specification
NO
Items
Specs
1
Sizes and weight
83x63x48;250g
2
Dimension of inlet
13.8mm
3
Dimension of outlet
10mm
4
Driving method 
Brushless, Magnetic , 2 phase or 3 phase
5
Pump material
PA66+GF30% (optional)
6
Condition of use
Continuously 
7
Fluids 
Water, oil, gasoline, acid and alkali solution etc
8
Max working temp
60degree(2 phase)or 100degree(3 phase)
9
Power consumption
2.5W~26.4W
10
Rated voltage
12Vdc or 24Vdc
11
Voltage used
5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc
12
Max rated current
1.2A
13
Max flow rate
10.8L/MIN(2.86G/MIN)
14
Max Static Head
7m(23ft)
15
Noise
<35dB
16
Water proof class
IP68(can be submersible installed)
17
Life span
More than 30000hrs
18
Power supply
Solar panel; DC electric source; battery 
Features
1,Brushless, permanent magnetic rotor, maintenance-free, long life
2,small size, high efficiency, low consumption, low noise
3,Ceramic sleeve and ceramic shaft [optional]
4,Stator and circuit board sealed by epoxy resin, completely water proof
5,Parameter adjustable, 12v pump’s head can be 2m to 5m..
6,Can be customized
Difference between 2-phase and 3-phase sensor less BLDC pump
2-Phase
u Driven by sensor which should be put inside the pump body
3-Phase
u Driven by program, sensor less, whole control circuit can be put outside
u Speed adjustable by PWM, analog signals(0-5v) or potentiometer[optional]
u Locked-rotor and reverse connection protection
u Automatic overload protection and over-temperature protection
u Soft start with low in-rush current, great for PV panel
Model Note
DC40-XX YY
 
1,DC--------means the pump is brushless dc pump
2,40---------Sizes: 40 means the size is at the range of 4cm 
3,XX--------voltage :12 means the voltage is 12Vdc
4,YY---------Head: 30 means the pump head is 3m
 
 
Parameters (The technical specification only for reference, it can be customized)
model
voltage
Rated current
head
flow
power
V
A
m
ft
L/H
G/H
w
DC40-0510
5
0.5
1.0
3.5
250
66
2.5
DC40-0615
6
0.6
1.5
4.9
300
79
3.6
DC40-0935
9
1.10
3.5
11.4
420
122
9.9
DC40-1220
12
0.45
2.0
6.5
350
93
5.4
DC40-1230
12
0.70
3.0
9.7
400
106
8.4
DC40-1240
12
1.00
4.0
13.0
460
122
12.0
DC40-1250
12
1.20
5.0
16.0
520
137
14.4
DC40-2430
24
0.35
3.0
9.7
400
106
8.40
DC40-2440
24
0.50
4.0
13.0
460
127
12.0
DC40-2450
24
0.55
5.0
16.0
520
148
14.4
DC40-2460
24
0.80
6.0
19.5
580
153
19.2
DC40-2470
24
1.15
7.0
22.7
620
164
26.4
Remarks
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.
Head-Flow curve Graph