DC50A Series
Specification
NO
|
Items
|
Specs
|
1
|
Sizes and weight
|
105.5x84x64;480g
|
2
|
Dimension of inlet
|
27mm
|
3
|
Dimension of outlet
|
27mm
|
4
|
Driving method
|
Brushless, Magnetic , 2 phase or 3 phase
|
5
|
Pump material
|
PA66+GF30% (optional)
|
6
|
Condition of use
|
Continuously
|
7
|
Fluids
|
Water, oil, acid and alkali solution etc
|
8
|
Max working temp
|
60degree(2 phase)or 100degree(3 phase)
|
9
|
Power consumption
|
2.5W~45.6W(2 phase) 2.5W~86.4W(3 phase)
|
10
|
Rated voltage
|
12Vdc or 24Vdc
|
11
|
Voltage used
|
5Vdc ~ 12Vdc or 5Vdc ~ 24Vdc
|
12
|
Max rated current
|
1.9A(2 phase)or 3.6A(3 phase)
|
13
|
Max flow rate
|
42L/Min(11GPM) ---2 phase 60L/Min(19GPM) ---3 phase
|
14
|
Max Static Head
|
3.5m(11.5ft)---- 2 phase 5.0m(16.5ft)---- 3 phase
|
15
|
Noise
|
<40dB
|
16
|
Water proof class
|
IP68(can be submersible installed)
|
17
|
Life span
|
More than 30000hrs
|
18
|
Power supply
|
Solar panel; DC electric source; battery
|
Features
l Brushless, permanent magnetic rotor, maintenance-free, long life
l small size, high efficiency, low consumption, low noise
l Ceramic sleeve and ceramic shaft [optional]
l Stator and circuit board sealed by epoxy resin, completely water proof
l Parameter adjustable, 12v pump’s head can be 1.5m to 3.5m..
l Can be customized
Difference between 2-phase and 3-phase sensor less BLDC pump
2-Phase
|
u Driven by sensor which should be put inside the pump body
|
3-Phase
|
u Driven by program, sensor less, whole control circuit can be put outside
u Speed adjustable by PWM, analog signals(0-5v) or potentiometer[optional]
u Locked-rotor and reverse connection protection
u Automatic overload protection and over-temperature protection
u Soft start with low in-rush current, great for PV panel
|
Model Note
DC50A-XX YY
1,DC--------means the pump is brushless dc pump
2,50---------Sizes: 50 means the size is at the range of 5cm
3,A---------differentiate outlet and inlet from DC50
4,XX--------voltage :12 means the voltage is 12Vdc
5,YY---------Head: 30 means the pump head is 3m
Parameters (The technical specification only for reference, it can be customized)
Model
|
Voltage
|
Current
|
Head
|
Flow
|
Power
|
V (dc)
|
A
|
m
|
L/H
|
w
|
|
DC50A-1223S
|
12
|
2.60
|
2.30
|
2000
|
31.2
|
DC50A-1223A
|
|||||
DC50A-1230S
|
12
|
3.00
|
3.00
|
2200
|
36.0
|
DC50A-1230A
|
|||||
DC50A-1235S
|
12
|
3.80
|
3.50
|
2500
|
45.6
|
DC50A-1235A
|
|||||
DC50A-2423T
|
24
|
1.30
|
2.35
|
2000
|
31.2
|
DC50A-2423S
|
|||||
DC50A-2423A
|
|||||
DC50A-2435T
|
24
|
1.90
|
3.50
|
2500
|
45.6
|
DC50A-2435S
|
|||||
DC50A-2435A
|
|||||
DC50A-2440S
|
24
|
3.00
|
4.00
|
2900
|
72.0
|
DC50A-2440A
|
|||||
DC50A-2450S
|
24
|
3.60
|
5.00
|
3600
|
86.4
|
DC50A-2450A
|
|||||
Remarks
|
The current above is open outlet current, when contact to circulation system the current will cut down to 55%~70% of Rated current.
|