China factory VOC monitor
VOC monitor Description:Features
u Real time monitor ambiance air quality
u Semiconductor mix gases sensor with 5 year life
u Gas detection: cigarette smoke, VOCs such as formaldehyde and toluene, ethanol, ammonia, hydrogen sulfide, sulfur dioxide and other harmful gases
u Monitor temperature and relative humidity
u Three-color (green/orange/red) LCD backlit indicating air quality at optimal/moderate/poor
u Preset warning point of buzzer alarm and backlight
u Provide one relay output to control a ventilator
u Modbus RS485 communication optional
u High quality technics and elegant appearance, best choice for home and office
u 220VAC or 24VAC/VDC power selectable; power adaptor available; desktop and wall mounting type available
u EU standard and CE-approval
u Semiconductor mix gases sensor with 5 year life
u Gas detection: cigarette smoke, VOCs such as formaldehyde and toluene, ethanol, ammonia, hydrogen sulfide, sulfur dioxide and other harmful gases
u Monitor temperature and relative humidity
u Three-color (green/orange/red) LCD backlit indicating air quality at optimal/moderate/poor
u Preset warning point of buzzer alarm and backlight
u Provide one relay output to control a ventilator
u Modbus RS485 communication optional
u High quality technics and elegant appearance, best choice for home and office
u 220VAC or 24VAC/VDC power selectable; power adaptor available; desktop and wall mounting type available
u EU standard and CE-approval
So the key point is to monitor and control the environment we live in, and make invisible pollution visible.
As there are many kinds of harmful gases in the air, it become really cost to monitor every single kind of air. It is recommended that CO and IAQ be monitored at home, and CO2, CO and VOCs in classroom and office.
G02-VOC monitor is specially designed to detect indoor air quality in offices and home environments. Its internal mix gases sensor has high sensitivity not only to VOC's such as toluene and formaldehyde from wood finishing and construction products but also to other air contaminants which are emitted by cigarette smoke, ammonia, hydrogen sulfide etc. It’s also sensitive to carbon monoxide, alcohol, disinfectant and other bad smells. So it is more suitable for monitoring IAQ than any other sensor that for a single kind of gas.
u Ventilation systems
u Air cleaning systems.
u Installation place such as bedroom, sitting room, study and dinner room, kindergarten, classroom, office, car, restaurant, and other public places.
Specifications
Gas detection
|
Highly sensitive to many harmful gases, such as harmful gases from construction and decoration materials, VOCs (like toluene and formaldehyde); Cigarette smoke; Ammonia and H2S and other gases from household wastes; CO, SO2 from cooking and burning; Alcohol, Natural gas, detergent and other bad smells etc. | |
Sensing element
|
Semiconductor mix gas sensor of long working life and good stability | |
Signal update
|
1s
|
|
Warm up time
|
72 hours (first time), 10 mins (normal operation) | |
VOC measuring range
|
0~30ppm ( 1ppm= 1 part per million
|
|
Display resolution
|
0.1ppm
|
|
VOC setting resolution
|
0.1ppm
|
|
Temperature & Humidity Sensor |
Temperature
|
Relative Humidity
|
Sensing element
|
NTC 5K
|
Capacitive sensor
|
Measuring range
|
0~50℃
|
0 -95%RH
|
Accuracy
|
±0.5℃ (25℃, 40%-60%RH)
|
±3%RH (25℃, 40%-60%RH)
|
Display resolution
|
0.5℃
|
1%RH
|
Stability
|
±0.5℃per year
|
±1%RH per year
|
Output
|
1xRelay output to control a ventilator or air-purifier,
max current 3A resistance(220VAC)
|
|
Warning alarm
|
Inner buzzer alarm and also three colors backlit switch as well | |
Buzzer alarm
|
Alarm starts when VOC value above 22ppm
|
|
LCD backlit
|
Green—optimal air quality ? enjoy the air quality Orange—moderate air quality ? ventilation suggested
Red—-poor air quality ? ventilation immediately
|
|
RS485 interface (option)
|
Modbus protocol with 19200bps | |
Operation condition
|
-20℃~60℃ (-4℉~140℉)/ 0~ 95% RH
|
|
Storage conditions
|
10℃~50℃/ 20%~ 60% RH
|
|
Net Weight
|
190g
|
|
Dimensions
|
130mm(L)×85mm(W)×36.5mm(H)
|
|
Installation standard
|
Desktop or wall mount (65mm×65mm or 85mmX85mm or 2”×4” wire box) | |
Wiring standard
|
Wire section area <1.5mm2
|
|
Power supply
|
9~24VAC/VDC, 220VAC±10% 50/60HZ
|
|
Consumption
|
2.8 W
|
|
Quality System
|
ISO 9001
|
|
Housing
|
PC/ABS fire-proof, IP30 protection
|
|
Certificate
|
CE
|
Model
|
Name
|
Description
|
Power
|
Type
|
G02-VOC-B320A
|
IAQ, temperature and humidity monitor/alarm | Three-color backlit LCD, buzzer alarm |
220VAC±10% (50/60HZ)
|
Wall mounting
|
G02-VOC-B332C
|
IAQ, temperature and humidity monitor/alarm | Three-color backlit LCD, buzzer alarm |
10~24VAC/VDC, with DC socket and a power adaptor
|
desktop,
with a bracket
|
G02-VOC-B340A
|
IAQ, temperature and humidity monitor/controller | Three-color backlit LCD, buzzer alarm; 1 on/off output; touch-key for operation |
220VAC±10% (50/60HZ)
|
Wall mounting
|
G02-VOC-B310A
|
IAQ, temperature and humidity monitor/alarm | Three-color backlit LCD, buzzer alarm. Modbus RS485 interface |
220VAC±10% (50/60HZ)
|
Wall mounting
|
G02-VOC-B380A
|
IAQ, temperature and humidity monitor/alarm | Three-color backlit LCD, buzzer alarm; 1 on/off output; touch-key for operation Modbus RS485 interface |
220VAC±10% (50/60HZ)
|
Wall mounting
|