Fujikura FSM-60S Fusion Splicer Kit w/ Fiber Cleaver
ALiTester offers a one year manufacturer’s warranty on Fujikura FSM-60S fiber splicing machine.
Features:
• Fujikura FSM-60S Fusion Splicer
• Fujikura CT-30A High Precision Fiber Cleaver w/ Hard Case & Instuction Sheet
• Fujikura ADC-13 AC Adapter/Battery Charger
• Fujikura BTR-08 Battery Pack
• Fujikura DCC-14 Battery DC Charger Cord
• AC Power Cord
• RS232 PC Interface Cable
• Spare Electrode Set
• Cooling Tray
• Carrying Strap
Specifications:
ALiTester offers a one year manufacturer’s warranty on Fujikura FSM-60S fiber splicing machine.
Features:
• Fujikura FSM-60S Fusion Splicer
• Fujikura CT-30A High Precision Fiber Cleaver w/ Hard Case & Instuction Sheet
• Fujikura ADC-13 AC Adapter/Battery Charger
• Fujikura BTR-08 Battery Pack
• Fujikura DCC-14 Battery DC Charger Cord
• AC Power Cord
• RS232 PC Interface Cable
• Spare Electrode Set
• Cooling Tray
• Carrying Strap
Specifications:
Applicable type of fibers |
SM (ITU-T G.652) MM (ITU-T G.651 DS (ITU-T G.653) NZDS (ITU-T G.655) |
Fiber Count
|
Single
|
Applicable fiber dimensions
|
Cladding Diameter: 80 to 150μm.
Coating diameter: 100 to 1000μm |
Fiber setting and cleaved length
|
Sheathe clamp A (standard): For coating dia. up to 250μm (8 to 16mm cleave)
coating dia. of over 250μm (16μm cleave) Sheathe clamp B (option): For coating dia. up to 1000μm (8 to 16mm cleave) Sheathe clamp C (option): For 900μm dia. loose tube fiber (8 to 16mm cleave) Fiber holder (option): FH-60-250 and FH-60-900 (10mm cleave) |
Splicing modes
|
Total 100 modes
|
Typical splice loss
|
0.02dB with SM
0.01dB with MM 0.04dB with DS 0.04dB with NZDS (Measured by cut-back method relevant to ITU-T standard) |
Return loss | >>60dB |
Splicing time
|
Typical 9 sec. with SM FAST
10 sec. with SM AUTO 13 sec. with AUTO modes with standard SM (ITU-T G.652) |
Arc Calibration Method
|
Automatic
Real-time and by using results of previous splice when in AUTO mode Manual arc calibration function available |
Splice Loss Estimate
|
Available
|
Attenuation splice function
|
Intentional high splice loss of 0.1dB to 15dB (0.1dB step) can be made for an in-line fixed attenuator.
|
Tube heater / heating time
|
Built-in tube heater with 30 heating modes / Typical 30 sec. with Fujikura FP-03
|
Applicable protection sleeve
|
60mm 40mm and Fujikura FPS01 series
|
Storage of splice result
|
the last 2000 results to be stored in the internal memory
|
Tension test
|
1.96 to 2.25N
|
Operating condition
|
0 to 5,000m above seal level, 0 to 95%RH and -10 to 50oC and up to 15m/s wind velocity, respectively
|
Storage Condition
|
0 to 95%RH and -40 to 80oC respectively. Battery: -20 to 30o for long term
|
Dimensions
|
136Wx161Dx143H (mm) excluding rubber foot
|
Weight
|
2.3kg with AC adaptor ADC-13
2.7kg with battery BTR-08. |
Viewing method and display
|
Two CMOS cameras and 4.1" color LCD monitor
|
Fiber view and magnification
|
X/Y (300X magnification), or both X and Y simultaneously (187X magnification)
|
Power Supply
|
Applicable voltage from 100 to 240V AC or 10 to 15V DC with ADC-13. 13.2V DC with BTR-08
|
No. of splice cycles with battery
|
Typical 160 cycles (splice / tube heat) with BTR-08
|
Electrode Life
|
2500 arc-discharges
|
Terminals |
USB 1.1 (Mini-B type) connector for PC communication. 6-pin Mini-DIN connector for HJS-02, HJS-03 or SH-8C power supply |