¨ temp. and RH% controller
temp. and RH% controller Features
relative humidity by control a humidifier or
dehumidifier
u Temperature detection and control optionalu Microprocessor makes detection and controlling
more accurately
u Provide two accuracies types with differentaccuracy sensors
u LCD can display working status such as %RH,
temperature, set point, and device mode, etc.
Makes reading and operating easy and accurate
u All models feature user-friendly setting buttons
u Enough parameters setup let the controller meeting
them power failure
u Lock function avoids wrong operation and makes
setting to be held
u Provide one or two max. 5 amp dry contact outputs.u Infrared Remote Control (optional)
u Blue backlight (optional)
u RS 485 communication interface (optional)
u External sensors (optional)
u We also provide other wall mounting and duct mounting humidity controllers, please see the high accuracy hygrostat THP/TH9-Hygro series and THP –Hygro16 Plug-and-Play high-power humidity controller.
¨ Buttons and LCD
|
|
|||||
Product Name |
Model
|
Description
|
Power supply:
-(A)/(B)/(C)
A: 230VAC B: 110VAC C: 24 VAC |
F2000LB-H1-(C )
|
Monitoring temperature, setting humidity, 1 ON/OFF triac output to control a humidifier or a dehumidifier. |
F2000P-TH-K01-(A)/(B)(C)
|
Detection temperature and humidity, 1XON/OFF relay output to control a humidifier or dehumidifier. The max. current is up to 5A. | |
F2000P-TH-K01-a
|
High accuracy for F2000P-TH-K01
|
|
F2000P-TH-K02-(A)/(B)(C)
|
Detection temperature and humidity, 2 ON/OFF relay outputs to control humidifier/ dehumidifier and a cooling/heating device. The max. current is up to 5A. |
|
F2000P-TH-K02-a
|
High accuracy for F2000P-TH-K02
|
|
F2000P-TH-K01-WT-(A)/(B)(C)
|
High accuracy version. Detection temperature and humidity, 1XON/OFF relay output to control a humidifier or dehumidifier., It uses an external compositive digital sensor (WT) | |
F2000P-TH-K02-WT-(A)/(B)(C)
|
High accuracy version. Detection temperature and humidity, 2 ON/OFF relay outputs to control humidifier/ dehumidifier and a cooling/heating device. It uses the external compositive digital sensor (WT) | |
Humidity Controller with RS485 interface |
F2000PC-TH-K01-(A)/(B)(C)
|
High accuracy version. Detection temperature and humidity, 1XON/OFF relay output to control a humidifier or dehumidifier. RS485 communication interface. |
F2000PC-TH-K02-(A)/(B)(C)
|
High accuracy version. Detection temperature and humidity, 2XON/OFF relay outputs to control a humidifier/dehumidifier and a AC device or a fan. RS485 communication interface. | |
Split Humidity Control Unit |
F2000PC-TH-01-TSM-(A)/(B)(C)
|
Humidity controller with temperature detection, it’s used with a external sensor box (wall mounting type or duct type) together via RS485 connection |
F2000PC-TH-02-TSM-(A)/(B)(C)
|
Temperature &humidity controller , it’s used with a external sensor box (wall mounting type or duct type) together via RS485 connection | |
External sensor box F2000TSM-TH-M101-N |
Wall mounting external sensor box with the humidity sensor inside. It must be connected with F2000PC-TH-01-TSM by RS485. The maximum connecting length is 100 meters. |
|
External sensor box
F2000TSM-TH-M201-N
|
Wall mounting external sensor box with the humidity& temperature sensors inside. It must be connected with F2000PC-TH-02-TSM by RS485. The maximum connecting length is 100 meters. | |
External sensor box F2000TSM-TH-D101-N |
Duct type of external sensor box with the humidity sensor inside. It can be put into an air duct and must be connected with F2000PC-TH-01-TSM by RS485. | |
External sensor box F2000TSM-TH-D201-N |
Duct type of external sensor box with the humidity sensor inside. It can be put into an air duct and must be connected with F2000PC-TH-02-TSM by RS485. | |
Options for Above Models | ||
Accessories
|
Back light-EL |
Blue back light displaying
|
Remote receiving-R | Remote control humidity with the infrared hand held controller |
¨ Specifications
|
Power supply
|
230VAC/110VAC/24VAC selectable at placing the order
|
|
|||
|
Output
|
F2000LB-H1: triac resource output
F2000P-TH series: 5A relay for the On/Off outputF2000PC-TH-K01/K02: 5A relay for the On/Off output |
|
|||
|
Displaying
|
LCD
|
|
|||
|
Connection length between the controller with the external sensor box | Maximum 100 meters |
|
|||
|
Net weight of the controller
|
F2000LB-H1: 230g
F2000P-TH Series: 280g
|
||||
|
Dimensions
|
F2000LB: 120mm(L)×90mm(W)×24mm(H)
F2000P-TH: 120mm(L)×90mm(W)×32mm(H)
|
||||
|
Mounting standard
|
Wall mounting in the wire box of 2”×4” or 65mm×65mm | ||||
Sensors spec.
|
Temperature
|
Humidity
|
|
|||
Accuracy
|
±0.5℃
±0.4℃ -high accuracy version |
±3%RH (30%-70%RH)
±2.5% RH (20%-80%RH)- high accuracy version
|
|
|||
Measuring range
|
0℃~60℃
|
0~100%RH-high version
|
|
|||
Display resolution
|
5℃
0.1℃-high version |
1% RH
0.1%RH-high version
|
|
|||
Stability
|
±0.1℃
|
±1%RH per year
|
|
|||
Storage environment
|
10℃-50℃, 20%RH~60%RH |
|
||||