Product Main

Specifications

Description
 
ACD-2K Pressure Controller is provided with alarm control function on the basis of ACD-201 Digital Pressure Gage functions, status display and alarm relay contacts output are provided, the upper and lower limit alarm points can be set, and return difference can be controlled, ACD-2K can also drive the relay output. Signal isolation design, without any interference, the standby lithium battery is built-in, which could work 5 to 8 years continuously, the acquisition pressure can be stabilized when the external power is broken off ( but the output signal is invalid); the advantages of pressure controller are high control accuracy, fast response speed, stable performance, small in size, convenient installation, etc., is the ideal electric-contact pressure gauge. The construction can be selected from radial direction type, axial direction type and panel mounting type.
 
Applications
 
l       Accuracy is up to Grade 0.05, can meet the high accuracy pressure acquisition, control and alarm requirements
l       Meet pressure control requirement of corrosivity, impact strength, vibration and other conditions
l       Calibration of pressure( differential pressure) transmitter, precision pressure gauge, general pressure gauge, sphygmomanometer and other pressure gauge
l       Substitute of electric contact pressure gauge, also it can be used as standard pressure gauge
 
Features
 
l       Optional RS485 and 4~20mA current output
l       Magnetic pen induction button design
l       Visually display the percentage bargraph
l       Acquisition speed can be set
l       Super power management technology, service life of battery can be used for 4 to 6 year
l       Signal full isolation technology
l       Anti electromagnetic interference and radio-frequency interference technology
l       Zero point homeostasis technology
l       Temperature composition technology
 
Data sheet
 
1.      Measurement Range: Gauge Pressure:-100kPa~0~1kPa~260MPa( Optional within the range)
                         Differential Pressure: 0~500Pa~3.5MPa( Optional within the range)
                         Absolute Pressure:0~10KPa~60MPa
2.       Output Signal: 4~20mA( 24VDC three-wire system), 1~5V
3.      Communication Method: RS485, RS232( output contacts belong to one group)
4.      Accuracy Grade: 0.05, 0.1, 0.2, 0.5
5.      Limit Control Accuracy: superior than 1%FS
6.      Display Mode: 5 digits dynamic display, percentage bargraph
7.      Overload Pressure: 1.5-3 multiple range, which depends on measurement range
8.      Built-in Power Supply: 3.6V high power lithium battery
9.      External Power Supply: 10~30VDC
10.  Relay Load Capacity: 240VAC/1A, 30VDC/2A
11.  Medium Temperature: -40℃~85℃
12.  Working Conditions: Temperature: -30℃~60℃; Humidity:<90%
13.  Process Link: M20*1.5 (external thread) or in accordance with customers demands
14.  Optional Accessories: Aluminum alloy suitcase, etc.