Description
 
 ACD-200L adopts the latest advanced micro power consumption intelligent instrument. The standby battery is built-in, which could work 5 to 8 years continuously, and the WVA segment type code and liquid crystal window with large screen is adopted. The reading are distinctive and clear. Optional shapes include radial direction type, axial direction type and panel mounting type.
 
Data Sheet
 
1.      Measurement Range:0~1mH2O~200mH2O
2.      Accuracy Grade: 0.1,0.2, 0.5
3.      Display Mode: dynamic 5 digits display, percentage progress bar;
4.      Overload Pressure: 1.5-3 multiple span, which depends on measurement range;
5.      Built-in Power Supply: 3.6V high power lithium battery;
6.      Medium Temperature: 0~70℃
7.      Working Conditions: Temperature: -30~60; Humidity:<90%
                      Temperature:0~50 (temperature for Grade 0.05); Humidity:<90%