Product Main

Specifications

Feature
• Touch-screen (TFT) and keyboard synchronous operation
• Single-phase and three-phase measurement, two in one
• Test all metering units and power meters of both high and low volt under 10KV
• Combination of electricity meter tester and power quality analyzer
• Online monitor for real-time data testing and comparison
• Safe and quick measurement for electricity anti-theft meter error
• Test result playback on screen and transferable to PC for report printing
• User-friendly interface and vivid screen display, simplify on-site testing of industrial and residential billing meters
• Different units could be used simultaneously in the circuit for comprehensive testing and troubleshooting

Technical Parameter
Voltage signal input: Direct input
• Resistance: >2MΩ, 20pF
• Testing range: 10~700Vrms
• Peak voltage: 1000V
• Power consumption: <0.5VA/phase
Current input circuit
• Indirect input, with different current clamps
• Testing range: 20Arms, 500Arms, 1000Arms
• Power consumption: <2.0VA/phase
Frequency range: 40 Hz ~70Hz
• Screen: 320*240, 5.7' TFT LCD touch-screen
• Internal Memory: 16 MB Flash
• External Memory: 256MB
• Com port: USB port
• Power supply: rechargeable Li-ion battery
workable for 5~6 hours
• Power adaptor: AC100~240V/DC16.8V-1A adaptor

• Main unit: 1.2kg, 277x169x36mm
• Working temperature: -20~40℃
• Relative humility: 5~90%RH
• Insulation: >2MΩ, AC1500V/50Hz, 1 min
Communication between main unit and extension unit
• Transmitting frequency: 433MHz
• Communication distance: >800 meters
• Frequency modulation: FSK
Optional thermal printer for instant print-out


Functionality

Function
Description
Low-volt measurement

Could test 3-phase 4 wire metering units and single-phase power meters

High-volt measurement
Could test high voltage metering units and power meters
High-Low volt CT ratio
Test high-volt CT and low-volt CT
Online measurement

Active power, reactive power and power factor of 3-phase 4 wire circuit

Harmonics Measurement

Harmonic measurement up to 50 Times. Test result includes: each harmonic voltage, harmonic current amplitude, Total Harmonic Distortion (THD), voltage harmonic/ current harmonic ratio (HR) and harmonic spectrum.

Test result playback

Convenient playback of testing result


Technical Parameter:
Specification
Testing range
Accuracy
Voltage/current/
frequency

3-phase voltage: 10~700Vrms
3-phase current: 0.5~1000Arms
Frequency: 40~70Hz

Voltage: ±0.5%
Current: ±0.5%
Frequency: ±0.01Hz
Harmonic testing

Voltage harmonic: total harmonic+1~50 th
Current harmonic: total harmonic+1~50 th

Voltage harmonic: ±0.1(%r)
Current harmonic: ±1%
Power measurement

Active power: 0.05~700kW
Apparent: 0.05~700kVA
Reactive power: 0.05~700KVAR
Power factor: 0.00~1.00
KWh: 0.01~10000kWh
KVAh: 0.01~10000kVAh
kVARh: 0.01~10000 kVARh
Average Total Power Factor : 0.00~1.00

Active Power: ±1%
Apparent Power: ±1%
Reactive Power:±1%
Power Factor: ±0.005
Active Energy: ±1%
Apparent Energy: ±1%
Reactive Energy: ±1%h
Average Power Factor: ±0.005