Product Main

Specifications

AC Power Supply / DC Digital Power Meter--AN8721P (F)/AN8711P(F)
Description of Digital Frequency Meter:
Main Features:
◆Power resolution is 0.1mW, minimum test current is 0.2mA, suitable for lower than 1W wait mode power consumption test
◆AC, DC of voltage, current, power, large LCD display, large information
◆High wave crest factor, more suitable for test big distortion load
◆1%~120% of range can ensure the accuracy
◆Fast test speed, satisfy production line fast test requirement
Technical Index:

Technical Parameter
AN8721P(F)
AN8711P(F)
Rated Voltage Test Range
60V/300V/600V, (1%~120%)× rated range
Rated Current Test Range
20mA/200mA/2A/20A ,
(1%~120%)× rated range
2.000A/20.00A/40.00A ,
(1%~120%)× rated range
Voltage/ Current Precision
AN8721P(F)
DC: ± (0.2%× reading+0.2%× range);
10Hz≤ f<45Hz: ± (0.1%× reading+0.2%× range);
45Hz≤ f≤ 66Hz: ± (0.1%× reading+0.1%× range);
66Hz<f≤ 1kHz: ± (0.1%× reading+0.2%× range)
In 0~18℃ or 28~40℃, add 0.03%of reading/℃
AN8711P(F)
DC: ± (0.3%× reading+0.2%× range);
45Hz≤ f≤ 66Hz: ± (0.4%× reading+0.1%× range);
66Hz<f≤ 500Hz: ± (0.3%× reading+0.2%× range)
In 0~18℃ or 28~40℃, add 0.03%of reading/℃
Active Power Test Range
0.0001~12kW
1.2W~ 24.00kW
Active Power Test Precision
AN8721P(F)
DC: ± (0.3%× reading+0.3%× range)
PF=1 ± (0.1%× reading+0.1%× range)(45Hz≤ f≤ 66Hz)
± (0.3%× reading+0.2%× range)(10Hz≤ f<45Hz, 66Hz<f≤ 1kHz)
PF=0 based on PF=1, add 0.2% of reading
0<PF<1 based on PF=1, add 0.2%× tanφ of reading (φ is the phase difference of voltage and current)
In 0~18℃ or 28~40℃, add 0.03%of reading/℃
AN8711P(F)
DC ± (0.8%× reading+0.2%× range)
45Hz≤ f≤ 66Hz ± (0.4%× reading+0.1%× range)
66Hz In 0~18℃ or 28~40℃, add 0.03%of reading/℃
Power Factor Measurement Range and Precision
0.100 ~1.000  
± 0.02 (The peak of voltage and current is more than 10% of range)
Frequency Range
DC; 10 ~1000Hz
DC; 45 ~500Hz
Frequency Precision
± (0.1%× reading)
(The peak of voltage and current is more than 10% of range)
Electric Power Range and Precision
0~99999MWh, ± (0.5%× reading)
(accumulated larger than 10000)
/
Electric Power Accumulated Time and Precision
0~9999hr 59min 
± 1sec/hr
Dimension W× H× D(mm)
213× 88× 386
Weight
About 3kg

We sincerely hope: communication, connecting you and me; to create the future.