Our power meter test series equipments have been the active players in the market since the year 1975 before PITE acquired Haiyan. With Haiyan's more than 35 years of rich experience and expertise in developing and manufacturing power meter calibrating equipments, PITE's new series testing systems have been widely applied by metrological institutes, QC department, test laboratories, meter manufact
PITE 9153 series are meter test equipments that can measure all types of single phase mechanical meters, electric mechanical meters and class 0.5 or lower electronic meters. It adopts operation ways of automatic semi-automatic or manual measurement. PITE offers different models of different accuracy to meet various customers' need for power meter calibration with different options for standard referenced meter and power amplifier.
Features:
• Modular design allows customized configurations on hardware and software, customer-friendly and future-proof
• Perform measuring like shunting, starting, basic errors, standard deviation and etc with multiple measurement modes: automatic, semi-automatic or manual measurement for power meters
• Able to measure all types of single phase mechanical meters, electric mechanical meters and electronic meters of class 0.5 or lower; different meters could be measured simultaneously
• There are error calculation reset buttons in error testing panel of each meter position; error of each meter is shown on LED display timely.
• Configured with specific meter connector of intelligent meter standard, connected at one time for measurement of voltage, current and small signal
• Measuring functions for current open-circuit, auto short-circuit and malfunction, and with optional modular for temperature monitor
• Use multilink protocol to convert server for communication protocol conversion, each meter position has independent RS485 interface for communication processing.
• Able to test output accuracy of meter timing pulse, and measure daily timing error
• Voltage auto searching color code, time saving for measurement of shunting and starting
• Able to calibrate different mechanical and electronic power meters or different constants at the same time
• Universal barcode input, and supports self-defined barcode
• Smart solutions for calibration with updateable software
• Temporary storage of data for later continued calibration
• Measures parameters of voltage, current, power factor, phase and frequency with real time display of vector graph
• Measure vibration caused by influence qualities like voltage, frequency, harmonics and external magnetic field
• Powerful PC software for data analyzing, waveform playback and detailed report exportation
• Harmonic testing adjustable from 2 to 21 times with harmonic distortion measurement
• Reserved MIS net interface and future proof for update
• Auto restore function for malfunction-protection
• Experiment for meter online countering ensures accuracy of power meters
Technical Parameter
PITE 9153 series are meter test equipments that can measure all types of single phase mechanical meters, electric mechanical meters and class 0.5 or lower electronic meters. It adopts operation ways of automatic semi-automatic or manual measurement. PITE offers different models of different accuracy to meet various customers' need for power meter calibration with different options for standard referenced meter and power amplifier.
Features:
• Modular design allows customized configurations on hardware and software, customer-friendly and future-proof
• Perform measuring like shunting, starting, basic errors, standard deviation and etc with multiple measurement modes: automatic, semi-automatic or manual measurement for power meters
• Able to measure all types of single phase mechanical meters, electric mechanical meters and electronic meters of class 0.5 or lower; different meters could be measured simultaneously
• There are error calculation reset buttons in error testing panel of each meter position; error of each meter is shown on LED display timely.
• Configured with specific meter connector of intelligent meter standard, connected at one time for measurement of voltage, current and small signal
• Measuring functions for current open-circuit, auto short-circuit and malfunction, and with optional modular for temperature monitor
• Use multilink protocol to convert server for communication protocol conversion, each meter position has independent RS485 interface for communication processing.
• Able to test output accuracy of meter timing pulse, and measure daily timing error
• Voltage auto searching color code, time saving for measurement of shunting and starting
• Able to calibrate different mechanical and electronic power meters or different constants at the same time
• Universal barcode input, and supports self-defined barcode
• Smart solutions for calibration with updateable software
• Temporary storage of data for later continued calibration
• Measures parameters of voltage, current, power factor, phase and frequency with real time display of vector graph
• Measure vibration caused by influence qualities like voltage, frequency, harmonics and external magnetic field
• Powerful PC software for data analyzing, waveform playback and detailed report exportation
• Harmonic testing adjustable from 2 to 21 times with harmonic distortion measurement
• Reserved MIS net interface and future proof for update
• Auto restore function for malfunction-protection
• Experiment for meter online countering ensures accuracy of power meters
Technical Parameter
Accuracy class
|
PITE 91XXD: 0.05
PITE 91XXC: -0.1 |
Output voltage
|
220V
0~120% consecutively adjustable Regulating fineness better than 0.01% |
Output Current:
|
0.01-100A
0~120% consecutively adjustable Regulating fineness better than 0.01% |
Output Power:
|
≥ 20VA for voltage circuit each meter position
≥ 25VA for voltage circuit each meter position |
Output power stability:
|
0.05 class equipments: ≤0.05%/120S PF=1.0
0.1class equipments: ≤0.1%/120S PF=1.0 |
Output wave distortion
|
≤0.5%
|
Frequency:
|
45~65HZ; regulating fineness: 0.01HZ,
|
Phase shifting range:
|
0°~360; regulating fineness: 0.1°
|
Stability of standard crystal oscillator:
|
10-7
|
Instruments Monitor class:
|
Voltage: 0.2
Current & frequency: 0.5 Phase: 0.5 |
Meter positions:
|
12, 24, 36 and 48 meters (customized configuration)
|
Power supply:
|
110V±10%, 60Hz or 220V±10%, 50HZ
|
Working environment:
|
Temperature: 20±5℃
35%<humidity<85% |