EK-FT-11 system is mainly used in the field of electric vehicles, the system is composed of EK-FT-C11 central control module, EK-FT-M1112 data collection module, also strong electric control, insulation test, touch screen and other functional modules can be added to the system;
The system has a high-precision voltage detector, current detection, temperature detection, SOC estimation algorithm, lossy balance, CAN BUS communication, RS485 communication, relay control, switch signal output, active signal input, cooling / heating control, data storage and other functions.
Product Features
The system has high accuracy in voltage, current and temperature data collection;
The system adopts a double isolation design; Each functional port is with protection, with high-security;
The system goes through EMC, high and low temperature, vibration, salt spray and other environmental testing, with strong reliability;
The system has efficient balance, one-way lossy balance maximum current can reach 250mA, and the balance fail-safe function is designed to protect the battery;
Real-time display of system information via the LCD screen or PC;
Support 2 ~ 8 G high-capacity data storage;
Reserved for the remote management interface, you can upload system date to server through a remote management module;
The system has multiple-way strong electrical control interface, isolate the control of weak and strong electric system, and improve effective immunity
The system has a high-precision voltage detector, current detection, temperature detection, SOC estimation algorithm, lossy balance, CAN BUS communication, RS485 communication, relay control, switch signal output, active signal input, cooling / heating control, data storage and other functions.
Product Features
The system has high accuracy in voltage, current and temperature data collection;
The system adopts a double isolation design; Each functional port is with protection, with high-security;
The system goes through EMC, high and low temperature, vibration, salt spray and other environmental testing, with strong reliability;
The system has efficient balance, one-way lossy balance maximum current can reach 250mA, and the balance fail-safe function is designed to protect the battery;
Real-time display of system information via the LCD screen or PC;
Support 2 ~ 8 G high-capacity data storage;
Reserved for the remote management interface, you can upload system date to server through a remote management module;
The system has multiple-way strong electrical control interface, isolate the control of weak and strong electric system, and improve effective immunity
| NO. | Names | Specifications |
| 1 | Voltage Detection | Maximum strings support from the voltage detector: 12 * n (n ≤ 25, total pressure ≤ 1000V) |
| Voltage detection range: 0 to 5 V (other voltages can be customized) | ||
| Voltage detection accuracy of ± 5mV | ||
| 2 | Temperature Detection | Temperature detection maximum support 3 * n (n ≤ 25) |
| Temperature sensing range of -40 ° C to 125 ° C | ||
| Temperature measurement accuracy ± 2 ° C (-40 ° C ~ 85 ° C) | ||
| 3 | Current Detection | Current ranges ± 1000A (Current sensor optional) |
| Current measurement accuracy of ± 1% | ||
| 4 | BCU module relay control | 3-way active output interface, 1-way passive output interface |
| Rated load current ≤ 1.2A, peak current ≤ 4A | ||
| 5 | BMU module relay control | 2-way relay control, rated load current ≤ 1.2A peak current ≤ 4A |
| 6 | Passive equilibrium | At the same time, can open 3-way balance under certain conditions, and different balances are independent of each other, the maximum current 250mA |
| 7 | Balanced failure protection | Effective protection of the battery safety |
| 8 | 485 conmmunications | 3-way 485 communication interface |
| 9 | BCU module CAN communications | 3-way CAN communication interface |
| 10 | BMU module CAN communications | 1-way CAN communication interface |
| 11 | Switching signal output | 4-way switch signal output, the maximum load current of 500mA |
| 12 | Active signal input | 2-way active signal input, 9 ~ 36V |
| 13 | Data Display | LCD screen can be connected through the 485 BUS |
| Can connect the host computer via 485 or CAN | ||
| 14 | SOC estimation error | < 5% |
| 15 | Failure alarm | Buzzer sound alarm |
| 16 | Data storage | Support 2 ~ 8G high-capacity SD data storage card |
| 17 | DTU interface | Reserved DTU Interface using 485 protocol |
| 18 | System power consumption | The BCU: 3W, the BMU: 0.5W |
| 19 | Operation voltage range | 12V system: DC9 ~ 18V (excluding LCD screen) |
| 24V system: DC18 ~ 32V (excluding LCD screen) | ||
| 20 | Operation tempreture range | -30 º C~ 75 º C |
| 21 | Storage Temperature range | -40 º C~ 85 º C |
| 22 | Dimensions (mm) | BCU module size: 165 * 106 * 43 |
| BMU module size: 124 * 91 * 40 |