Product Main

Specifications

Furnace and Boiler Blower Manufacturer

1.Applications

  Type G4-10 blowers are mainly used  in steam boiler,G4-10 may be used in mines for ventilation.The medium carried by ventilation fan is air and the max temperature must be below 80 degrees celsius;fue gas is carried by draught fan and the top  temperature can not exceed 250 degrees celsius. A dust collection device should be mounted in front of the draught fan to reduce the dust that may enter the fan.

 

2.Types and explantion

  The ventilators and the draught fans are single-suction,impellers with 13 specifications each from No 8 to No 29.5.The turn mode is coupling driving,in which we use elastic pin coupling.

 
3.The main figures
 
Type No.
Spindle Speed
(r/min)
Air Volume
(m3/h)
Total pressure
(KPa)
Motor Power
Type
Power
(Kw)
28F
730
332000
4.48
Y5603-8
6000V
1000
403200
4.32
474300
4.04
545500
3.56
616600
2.97
580
263700
2.83
Y50010-10
6000V
630
320300
2.73
376800
2.55
433300
2.25
489800
1.87
 
4.Structure

  The blowers mainly consist of impeller,base,inlet port, variable inlet vane damper and transmission part.

 
 5.Information for ordering

  When you make an order for our products ,please note clearly about the type ,volume,pressure,

outlet angle ,rotational direction ,and the specifications of the motor of fan .