Characteristics:
1. The device is small, with low power consumption; it is easy to replace the mould, it is easy operate and clean.
2. The device is standardization and serialization, for the parts can be interchanged, it will be convenient and accurate to replace the mould.
3. It is use high precision indexing device, the vibration is small, extreme load working noise is less than 75db. For the dose difference is controlled within ± 3%. For the domestic capsules probability is more than 99.5% and empty one is 99.9%.
4. The electrical components is adopt in Germany Siemens, Japan Omron and other well-known brands, for the control system is safe and reliable.
5. For the Work platform is made of 45 ≠ steel plate with hard chrome plating surface. It is hard to deformation, with no rust, hardness is high; For the parts which is in direct contact with the powder is made by high quality stainless steel 304,316, it is fully in compliance with pharmaceutical GMP requirements
6. It could be configured powder collecting device based on the user requirement. For the device could recover 90% loss material, to improve the economic benefits of the drug manufacturers.
7. For the function is complete. It will be alarm when hopper is no material and automatic shutdown when the empty capsule is not enough. It could be installed pellets, granules, tablets filling function according to user requirements. It could meet three kinds of materials, and could let the sustained-release, controlled release and tablet drugs to be packed into the same capsule.
8. For the measuring tray bottom is embedded sealed device, it is improved the situation of powder leakage, reduced parts worn down, washed easy. There is the board around dose tray; it is recycling the thrown powder effective according to the pipe, at the same time reducing work countertops dust.
9. It is avoided cross contamination and saved energy. For the capsule production output device is redesigned. Eliminating the need of air compressor, thus reducing the overall dimensions and the noise, avoid cross contamination and the breakdown caused by air discharge, in additional saved energy in this way.
10. Clearance adjustment of Dose disc convenient, only adjustment gear core angle, can led drive gear, makes 5 stay bolts go up or down; according to the characteristics of herbal medicine, increased cam size, nitrogen treatment cam surface, increased hardness on surface, ensure service life and safety in operation (cam is processed by five dimension fabricating machinery imported from Germany.)
11. Knob-trimming hand adjustment device, easy to adjust, disassembly and cleaning. Sealed device embedded at the bottom of measuring tray, improved leakage. Bracket passivated by import air craft aluminum, which is uniqueness in mainland of China; No static electricity, not to drink powder, easy to clean
12. Improve the structure of scraping device: improved traditional scraping device, make sure the first and the last hole of the measuring tray in the same hold of the power, improved the precision of powder install
13. Man-machine interface configured intelligent module, which adopts software from Germany Siemens. Complete monitoring function, for material shortages, lack of capsule, road blocks and operation break down, automatic alarm stop once there is any problem. Count out one by one by date and time, accurately to statistics the cumulative production.
Technical Data:
Model
|
RZJ-200A
|
RZJ-400A
|
RZJ-600A
|
RZJ-800A
|
RZJ-1000A
|
RZJ-1200A
|
Capacity(pieces /min)
|
200
|
400
|
600
|
800
|
1000
|
1200
|
Dimension (cm)
|
70×80×170
|
70×80×170
|
84×96×180
|
86×96×180
|
80×100×180
|
96×100×190
|
Capsule type:
|
00, 0, 1, 2, 3, 4, 5
|
|||||
Capsule probability
|
Empty 99.9% full Capsule >99.5%(domestic capsules)
|
|||||
Weight (kg)
|
700
|
700
|
800
|
900
|
950
|
1100
|
Difference
|
±3% -±4%
|
|||||
Working conditions
|
Ambient temperature :20-25 ° C, Humidity :40-50 ℃ ; If the drug sample is the powder type, it should meet the powder particle size at 40-60 mesh. The powder is with a certain plasticity, and if the drug is pellets type, it should meet the particle size at 10-15 mesh (with pellets / particle feeding device)
|
|||||
Holes No
|
2
|
3
|
5
|
6
|
8
|
9
|
Noise
|
<80DB(A)
|
<75DB(A)
|
<80DB(A)
|
|||
Cleaner
|
17.6Kpa 180m3/h
|
17.6Kpa 180m3/h
|
17.6Kpa 180m3/h
|
17.6Kpa 180m3/h
|
24.5Kpa 210m3/h
|
24.5Kpa 210m3/h
|
Power input
|
380V/220V 3 phase 4 wires, 50Hz
|
|||||
Power
|
Main body 1.1KW, vacuum pump 0.75kw, cleaner 1.1kw, feeding 0.18kw
|
Main body 1.5kw, vacuum pump 1.1kw, cleaner 2.2kw, feeding 0.18kw
|
Main body 1.5kw, vacuum pump 2.2kw, cleaner 2.2kw,feeding 0.18kw
|
|||
water supply requirements
|
With the circulating water tank, or connecting the external water source, 250L / H, 0.4Mpa
|