Product Main

Specifications

3CX2500H3_FU613F TRIODE
Output power 10 kW
General characteristics
Cathode
Thoriated tungsten
Heating
Direct
Filament
7.5±0.35 V
Filament current
51.5 A
Interelectrode capacitances (cathode earthed), approx.
Input
35 pF
output
0.9 pF
Grid-anode
20 pF
Amplification factor, average
22
Temperature on the surface the tube, max.
250℃
Anode cooling
forced air
Weight,( approx.)
2.9 Kg
Operating position
Vertical. Anode up/down
Maximum ratings
Frequency
75 MHz
Grid voltage
-1kV
Anode voltage
5.5Kv
Anode dissipation
2670W
Anode current
2A
Grid dissipation
150W
Typical operation
RF amplifier plate modulated
Example 1
Example 2
Example 3
Frequency
≤30
≤30
≤30
kW
Output power
5
5.3
5.3
kW
Anode voltage
4
4.5
5
kV
Grid bias voltage
-450
-500
-500
V
Anode current
1.67
1.47
1.25
A
Grid current
180
140
150
A