Stackable syringe pump JZB-1800C

Stackable to the maximum of 8 channels
ICU infusion workstation: stack 4 Syringe pump with 1 infusion pump to compose an ICU infusion workstation
Three work modes: Rate mode, Time mode and Weight mode
Compatible with any standard syringes( 10ml, 20ml,30ml, 50ml, 60ml) of any manufacturer
Automatic calibration for any brand syringes
Identify the specification of syringe automatically
Large color LCD screen, intuitive, easy operation
Audible and visual bubble detector, accurate and safety
High capacity of 8 hours internal rechargeable battery backup with syringe infused at 5ml/h
Three levels for occlusion pressure: high, middle and low
Three levels for alarm sound: high, middle and low
Auto KVO function: After liquid infusion finished, the pump automatically switch to mico-flow to prevent the thrombus
IPX4 to prevent splash
Application:
1. critical care of Human: ICU,CCU, Pediatrict Department, Newborn Room, Operation room, First Aid Room,Neonate Care,etc.
2. veterinary use : Animal hospital
 
Specifications:
Compatible Syringes: 5ml, 10ml, 20ml, 30ml, 50ml, 60ml of any standard
Delivery Rate Range: 50ml(60ml):     0.1ml/h~1800ml/h    (0.1ml/h step)
                  20ml(30ml):     0.1ml/h~800ml/h     (0.1ml/h step)
                  10ml:          0.1ml/h~400ml/h     (0.1ml/h step)
                   5ml:          0.1ml/h~200ml/h     (0.1ml/h step)
Time Mode: SOL.VOL: 0.1~999.9ml (0.1ml step)
Running Time: 1~1999min (1 min step)
Body weight mode: Sol.vol: 0.1~999.9ml     (0.1ml step)
                Drug mass: 0.1~999.9mg  (0.1mg step)
                Dose: 0.01~99.99ug/kg/min (0.01ug/kg/min step)
                     0.01~99.99mg/kg/h   (0.01mg/kg/h step)
                Weight:0.1~300kg         (0.1kg the least step)
 
Total volume range: 0.1~1999.9ml  (0.1ml step)
Purge rate: 50ml(60ml):      1800ml/h
         30ml:      800ml/h
         20ml:      800ml/h
         10ml:      400ml/h
         5ml:       200ml/h
KVO rate: 1ml/h
Bolus rate: 10ml: 10~300ml/h, 20ml(30ml): 10~600ml/h 50ml(60ml): 10~1200ml/h
Bolus volume: maximum of 25 ml
Shock protection: ClassⅠ,Type CF
Alarm function:
Near empty, Syringe empty, Volume complete(when limit voume has been set), Occlusion, Syringe loose, Operation errors, Low battery and device failures.
Power Source: AC power supply: AC 100 to 240V ±10%, 50, 60Hz;
            Internal Lithium battery: 11.1V, 2000mAh, Approximately 8 hours of contiuous operation on a new and fully charged battery with syringe running at 5ml/h
Power comsuption: ≤25VA
 
Application Environment:
Operation Condition:
Ambient temperature: 5~40 degree C
Relative humidity: 20~90%
 
Storage Condition:
Ambient Temperature: -10~55 degree C