Product Main

Specifications

Copper Ore Flotation Machine On Hot-Sale
*Large inhaling capacity, low consumption.
*Reasonable circulation of slurry
*Automatic controlling device
Application of Flotation Machine
Flotation machine is applicable for separating non-ferrous metal and ferrous metal, black metal, noble metal, non-metal mineral, raw materials of chemical industry, it is mainly used for coarse separation, swept separation, fine separation and flotation.
 
Working principle of Flotation Machine
The impellers are driven through V- belt transmission, which brings centrifugal effect to form the negative pressure. On one hand, the flotator inhales sufficient air to mix with ore pulp; on the other hand it stirs ore pulp and mix it with medication to form the mineralized bubble. Then adjust the height of flashboard and control the liquid surface so that the useful bubble can be scraped out by the scraper blade.
 
 Features of copper ore flotation machine
1.Large inhaling capacity and low consumption.
2.Complete flotation circuit with inhaling air and slurry, no auxiliares are needed.
3.Process is easy to be changed.
4.Reasonable circulation of slurry decreases coarse sand sedimentation.
5.Automatic controlling device makes adjustment more convenient.
 
Main technical parameters of flotation machine
Model
Trough
cubage
(m³)
Impeller
Power
Capacity
(M³/min)
Overall
dimension
(m)
Weight
(kg)
Dia.
(mm)
Speed
(r/min)
Impeller
(kw)
Scraper
(kw)
SF0.15
0.15
200
536
1.5
0.55
0.06-0.18
0.5*0.5*0.6
538
SF0.37
0.37
296
386
1.5
0.55
0.2-0.4
0.7*.07*0.75
936
SF0.7
0.7
350
400
3
1.1
0.3-0.9
0.9*0.82*0.95
1200
SF1.2
1.2
150
312
5.5
1.1
0.6-1.2
1.1*1.1*1.1
2745
SF2.8
2.8
550
268
11
1.1
1.5-3.5
1.7*1.6*1.15
4676
SF4
4
650
220
15
1.5
2-4
1.85*2.05*1.2
5165
SF8
8
760
191
30
1.5
4-8
2.2*2.9*1.4
4129
SF10
10
760
191
30
1.5
5-10
2.2*2.9*1.7
4486
SF20
20
760
191
30*2
1.5
5-20
2.85*3.8*2
9823
model
cell volume (mm)
impeller dia(mm)
capacity
(m³/min)
impeller speed
(r/min)
scraper speed
(r/min)
impeller motor
power
(kw)
scraper motor
power (kw)
size(mm)
L×W×H
weight
(t/cell)
XJK-0.13
0.13
200
0.05-0.16
600
17.5
1.5
0.55
2110*865*990
0.35
XJK-0.23
0.23
250
0.12-0.28
500
17.5
1.5
0.55
2625*1130*1290
0.41
XJK-0.35
0.35
300
0.18-0.4
470
17.5
3
0.55
3012*1350*1327
0.45
XJK-0.62
0.62
350
0.3-0.9
400
16
4
1.1
3789*1464*1530
0.85
XJK-1.1
1.1
500
0.6-1.6
330
26
5.5
1.1
4679*1820*1942
1.24
XJK-2.8
2.8
600
1.5-3.5
280
26
11
1.1
7750*1600*1100
2.43